Belt replacement

Page 9 highlights

36 36 Snap access door into place. Reposition dirt cup (Figs. 29-31). 38 Belt replacement The belt on your Hoover cleaner causes the agitator to rotate and is important for the effective operation of the cleaner. The belt is located under the hood of the cleaner and should be checked from time to time to be sure it is in good condition. When to replace Disconnect cleaner from electrical outlet. To check belt, remove hood and agitator cover as shown in Figs. 37 through 40. Replace belt if it is stretched, cut or broken. What to buy To assure effective operation, use only genuine HOOVER belts with your cleaner. When purchasing a new belt, ask for HOOVER part No. 40201190. 37 How to replace Disconnect cleaner from electrical outlet. 37 With the handle in the upright position, tilt cleaner back until it rests on floor. Remove the 2 screws near the front of the brush roll cavity. 39 40 M 38 Press on handle release pedal (M) and lower the nozzle so it is flat. Remove hose end (Fig.15). Remove 2 screws at rear of hood. 41 39 Lift hood off cleaner. 42 N 40 Remove the 2 screws behind the agitator cover. Remove agitator cover (N). 43 41 Remove agitator and used belt. Discard used belt. O 42 With lettering to the outside of belt, slide new belt along side of cleaner cavity and over motor pulley (O). P 43 Insert agitator through belt and place belt in belt guide (P). Continued § 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Belt replacement
The belt on your Hoover cleaner causes
the agitator to rotate and is important for
the effective operation of the cleaner.
The belt is located under the hood of the
cleaner and should be checked from
time to time to be sure it is in good con-
dition.
When to replace
Disconnect cleaner from electrical
outlet.
To check belt, remove hood and agitator
cover as shown in Figs. 37 through 40.
Replace belt if it is stretched, cut or bro-
ken.
What to buy
To assure effective operation, use only
genuine HOOVER belts with your
cleaner. When purchasing a new belt,
ask for
HOOVER part No. 40201190.
9
36
Snap access door into place.
Reposition dirt cup (Figs. 29-31).
37
38
How to replace
Disconnect cleaner from electrical
outlet.
With the handle in the upright
position, tilt cleaner back until it
rests on floor.
Remove the 2 screws near the front of
the brush roll cavity.
Press on handle release pedal
(M) and lower the nozzle so it is
flat.
Remove hose end (Fig.15).
Remove 2 screws at rear of hood.
39
Lift hood off cleaner.
40
Remove the 2 screws behind the
agitator cover.
Remove agitator cover (N).
41
Remove agitator and used belt.
Discard used belt.
42
43
With lettering to the outside of
belt, slide new belt along side of
cleaner cavity and over motor pulley
(O).
Insert agitator through belt and
place belt in belt guide (P).
Continued
M
N
P
O
36
37
38
39
42
43
40
41