7 • Completing Your Installation With or Without a Light Fixture (continued) 7-10.To attach the lower switch housing, connect the upper plug connector from the motor to the lower plug connector in the lower switch housing assembly. Note: Both plug connectors are polarized and will only fit together one way. Make sure the connectors are properly aligned before connecting them. Incorrect connection could cause improper operation and damage to the product. 7-11.Place the lower switch housing assembly over the upper switch housing. Align the side screw holes in the upper and lower switch housings. Attach the lower switch housing to the upper switch housing with three housing assembly screws. If you are not installing the light fixture, your installation is complete. Otherwise, proceed with step 7-12. 7-12.Install one screw-in CFL (compact flourescent) bulb (19 Watt Maximum). Do Not use incandescent bulbs in this fixture. 12 7-13 Insert the globe into the fixture. Install and tighten the thumbscrews manually. Do not overtighten. Note: If thumbscrews are pre-threaded, loosen the screws before inserting the globe, then retighten securely. Steps 7-6 - 7-7 Lower Switch Housing Plug Connector Detail Housing Assembly Screw Plug Connector CFL bulb (max 19W) Hunter Fan Company Globe Steps 7-12 - 7-13 42819-01 • 11/14/06 8 • Operating and Cleaning Your Ceiling Fan Step Title In warm weather, use downward air flow pattern In cold weather, use upward air flow pattern 8-1. Turn on electrical power to the fan. 8-2. The fan pull chain controls power to the fan. The pull chain has four settings in sequence: High, Medium, Low and Off. • Pull the chain slowly to change settings. • Release slowly to prevent the chain from recoiling into the blades. • The chain uses a breakaway connector that separates if the chain is jerked. If this happens, simply reinsert the chain into the connector. 8-3. The light pull chain controls power to the light. The pull chain has two settings: On and Off. 8-4. Ceiling fans work best by blowing air downward (counterclockwise blade rotation) in warm weather to cool the room with a direct breeze. In cold weather, having the fan draw air upward (clockwise blade rotation) will distribute the warmer air trapped at the ceiling around the room without causing a draft. 13 8-5. For cleaning finishes, use a soft brush or lint-free cloth to prevent scratching. A vacuum cleaner brush nozzle can remove heavier dust. Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth. You may use an artistic agent, but never abrasive cleaning agents as they will damage the finish. 8-6. Clean wood finish blades with a furniture polishing cloth. Occasionally, apply a light coat of furniture polish for added protection and beauty. Clean painted and high-gloss blades in the same manner as the fan finish. To Change Airflow Direction Turn the fan off and let it come to a complete stop. Slide the reversing switch on the fan to the opposite position. Restart fan. Reversing Switch 42819-01 • 11/14/06 Hunter Fan Company

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

12
Hunter Fan Company
42819-01 • 11/14/06
Step Title
13
42819-01 • 11/14/06
Hunter Fan Company
Lower Switch
Housing
Plug
Connector
Housing
Assembly Screw
Plug
Connector
Detail
Steps 7-6 – 7-7
7-10.To attach the lower switch housing, connect the upper plug
connector from the motor to the lower plug connector in the
lower switch housing assembly.
Note:
Both plug connectors are polarized and will only fit together
one way. Make sure the connectors are properly aligned before
connecting them. Incorrect connection could cause improper
operation and damage to the product.
7-11.Place the lower switch housing assembly over the upper switch
housing. Align the side screw holes in the upper and lower switch
housings. Attach the lower switch housing to the upper switch
housing with three housing assembly screws.
If you are not installing the light fixture, your installation is
complete.
Otherwise, proceed with step 7-12.
7-12.Install one screw-in CFL (compact flourescent) bulb (19 Watt
Maximum).
Do Not use incandescent bulbs in this fixture.
7-13 Insert the globe into the fixture.
Install and tighten the
thumbscrews manually.
Do not overtighten.
Note:
If thumbscrews are pre-threaded, loosen the screws before
inserting the globe, then retighten securely.
8-1. Turn on electrical power to the fan.
8-2. °e fan pull chain controls power to the fan. °e pull chain has
four settings in sequence: High, Medium, Low and Off.
Pull the chain slowly to change settings.
Release slowly to prevent the chain from recoiling into the
blades.
°e chain uses a breakaway connector that separates if the
chain is jerked. If this happens, simply reinsert the chain into
the connector.
8-3. °e light pull chain controls power to the light. °e pull chain has
two settings: On and Off.
8-4. Ceiling fans work best by blowing air downward (counterclockwise
blade rotation) in warm weather to cool the room with a direct
breeze. In cold weather, having the fan draw air upward (clockwise
blade rotation) will distribute the warmer air trapped at the
ceiling around the room without causing a draft.
8-5. For cleaning finishes, use a soft brush or lint-free cloth to prevent
scratching. A vacuum cleaner brush nozzle can remove heavier
dust. Remove surface smudges or accumulated dirt and dust using
a mild detergent and a slightly dampened cloth. You may use
an artistic agent, but never abrasive cleaning agents as they will
damage the finish.
8-6. Clean wood finish blades with a furniture polishing cloth.
Occasionally, apply a light coat of furniture polish for added
protection and beauty. Clean painted and high-gloss blades in the
same manner as the fan finish.
To Change Airflow Direction
Turn the fan off
and let it come to a complete
stop. Slide the reversing switch on the fan to the
opposite position. Restart fan.
In warm weather
, use
downward air flow pattern
In cold weather
, use upward
air flow pattern
8 • Operating and Cleaning Your Ceiling Fan
Reversing
Switch
CFL bulb
(max 19W)
Steps 7-12 – 7-13
Globe
7 • Completing Your Installation With or Without a Light Fixture (continued)