Hunter 28672 Owner's Manual - Page 8
standard, angled
View all Hunter 28672 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
3 • Assembling the Fan for Ceilings 9 Feet or Higher You can assemble your fan for standard or angled mounting as shown Steps 3-1 - 3-3 in steps 3-1 - 3-3. 3-1. To assemble fan to hang down from a flat or angled ceiling, place the canopy and canopy trim ring around the adapter so that they rest on the fan assembly. 3-2. Feed the wires from the fan through the downrod. Note: Make sure all the wires are on the same side of the metal dowel pin inside the dowrod. 3-3. Loosen the square head setscrew on the adapter to install the pipe and ball assembly. Note: When the pipe and ball assembly is fully installed, 2-3 threads on the pipe will still be visible; this is normal. Securely retighten the setscrew with a wrench or pliers. Adapter CAUTION: The adapter has a special coating on the threads. Do not remove this coating; the coating prevents the downrod from unscrewing. Once assembled, do not remove the downrod. WARNING: Do not carry or lift fan by canopy. 3-4. Raise the fan and place the ball into the hanger bracket. 3-5. Align the notch on the ball with the indent in the hanger bracket. (Rotate the fan until you hear the notch pop into place.) Go to 4 • Wiring the Fan. Steps 3-4 - 3-5 WARNING: Fan may fall if not assembled as directed in these installation instructions. Downrod Canopy Canopy Trim Ring Setscrew Indent 8 45068-01 • 05/19/10 • Hunter Fan Company