Mount Wallplate and Thermostat
View all Hunter 44550 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
INSTALLATION 12-13 Mount Wallplate and Thermostat s Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. (See Figure 2.) s Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided if your existing holes do not line up with those on the Hunter wallplate. s Drill holes with 3/16" bit and gently tap anchors into the holes until flush with wall. s Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and tighten. (See Figure 3.) OB RC G Y/Y1 W RH Figure 2 NOTE: 5-wire Systems Figure 3 If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and RC terminals on the wallplate. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals.