4 . Features (Cont.) Daylight Savings Time This thermostat allows for 1 touch daylight savings time change. To activate or deactivate the daylight savings time feature: Press the " daylight savings" button and hold for 3 seconds until the time changes. When daylight savings time is active, the icon will be displayed next to the current time. Indiglo® Backlight Your thermostat has an electroluminescent lamp that backlights the display for easy viewing in the dark. When any key is pressed, the backlight will be activated. The display will stay illuminated for 15 seconds after the last key is pressed. Note: The backlight not operate if the thermostat is in a "Low Battery" State. Filter Monitoring Your thermostat keeps a record of the number of hours your filter has been in use. To maximize your system's performance and energy efficiency, change or clean your system's filter regularly. When the total system run time for heat or cool reaches 500 hours, "FILTER" will alternate on the display with the day to remind you to clean or change your system's filter. "FILTER" will continue to display until the counter is set back to zero. To review total filter usage: Press the filter button to show filter usage. After 15 seconds the screen will reset to the main display, or you may press and release the ret/clear button as well. the filter monitor will display up to 999 hours and 59 minutes of usage. To reset the filter counter: hold the ret/clear button for 3 seconds while on the filter usage screen. The display will blink, and the counter will be reset to zero. Power Failure Protection In the event that power is lost, the batteries will act as backup, saving your settings and programs. Error Indicator If the thermostat is unable to control your system due to an unexpected problem, the thermostat will enter Error Mode. In this condition, the thermostat flashes "Error" and a code number on the LCD display, and shuts off your system. To correct this problem: Take a paperclip and insert it into the "reset hole" on the keyboard of the thermostat. Hold it in for a few seconds until the display goes blank. Remove the paperclip and the thermostat should reset back to factory condition. If this does not work, reinsert the paperclip into the "reset hole". While keeping the paperclip in the reset hole, remove the batteries from the thermostat. Continue holding the paerclip in for 10 seconds then remove it. Replace the batteries with a new set, even if they have recently been replaced. Warning: Using the reset hole to clear error mode will reset all programs and settings to factory. Your thermostat will need to be reprogrammed. Monitor your thermostats performance for the next few days. If you receive another error, contact our technical support department at 888-830-1326. Hours of operation are 7 AM to 7 PM Central Time Monday thru Friday and 8 AM to 5 PM Central Time on Saturday. Temperature Range Your thermostat can be programmed between 45°F and 95°F (7°C and 35°C). However, it will display room temperatures from 15°F to 99°F (-9°C and 37°C). "HI" will be displayed if the temperature is higher than 99°F (37°C), and "LO" will be displayed if the temperature is lower than 15°F (-9°C). 10 44008-01 • 02/10/10 • Hunter Fan Company

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

44008-01
02/10/10
Hunter Fan Company
10
10
°is thermostat allows for 1 touch daylight savings time change.
To activate or deactivate the daylight savings time feature:
Press the “
daylight savings” button and hold for 3 seconds until the time changes. When daylight savings time is active, the
icon will be displayed next to the current time.
Daylight Savings Time
4
.
Features (Cont.)
Your thermostat has an electroluminescent lamp that backlights the display for easy viewing in the dark. When any key is
pressed, the backlight will be activated. °e display will stay illuminated for 15 seconds after the last key is pressed.
Note:
°e backlight not operate if the thermostat is in a “Low Battery” State.
Indiglo® Backlight
Your thermostat keeps a record of the number of hours your filter has been in use. To maximize your system’s performance
and energy efficiency, change or clean your system’s filter regularly. When the total system run time for heat or cool reaches
500 hours, “FILTER” will alternate on the display with the day to remind you to clean or change your system’s filter. “FILTER” will
continue to display until the counter is set back to zero.
To review total filter usage:
Press the
filter
button to show filter usage. After 15 seconds the screen will reset to the main display, or you may press and
release the
ret/clear
button as well. the filter monitor will display up to 999 hours and 59 minutes of usage.
To reset the filter counter:
hold the
ret/clear
button for 3 seconds while on the filter usage screen. °e display will blink, and the counter will be reset to zero.
Filter Monitoring
In the event that power is lost, the batteries will act as backup, saving your settings and programs.
Power Failure Protection
If the thermostat is unable to control your system due to an unexpected problem, the thermostat will enter Error Mode. In this
condition, the thermostat flashes “Error” and a code number on the LCD display, and shuts off your system.
To correct this problem:
Take a paperclip and insert it into the “reset hole” on the keyboard of the thermostat. Hold it in for a few seconds until
the display goes blank. Remove the paperclip and the thermostat should reset back to factory condition. If this does not
work, reinsert the paperclip into the “reset hole”. While keeping the paperclip in the reset hole, remove the batteries from the
thermostat. Continue holding the paerclip in for 10 seconds then remove it. Replace the batteries with a new set, even if they
have recently been replaced.
Warning:
Using the reset hole to clear error mode will reset all programs and settings to factory. Your thermostat will need to
be reprogrammed.
Monitor your thermostats performance for the next few days. If you receive another error, contact our technical support
department at 888-830-1326. Hours of operation are 7 AM to 7 PM Central Time Monday thru Friday and 8 AM to 5 PM
Central Time on Saturday.
Error Indicator
Your thermostat can be programmed between 45±F and 95±F (7±C and 35±C). However, it will display room temperatures from
15±F to 99±F (-9±C and 37±C). “HI” will be displayed if the temperature is higher than 99±F (37±C), and “LO” will be displayed if
the temperature is lower than 15±F (-9±C).
Temperature Range