Husqvarna 536LiLX Operation Manual - Page 21

Troubleshooting schedule - lowe s

Page 21 highlights

MAINTENANCE Troubleshooting schedule Keypad Troubleshooting takes place from the keypad. Control panel Green activate LED flashing. Error LED flashes. The machine does not start Error LED is lit with red light. Possible faults Low battery voltage. The power trigger and the activate button are pressed at the same time. Overload. Temperature deviation. Dirt in battery connectors. Service Possible action Charging the battery Release the power trigger and the machine is active. The trimmerhead is jammed. Remove the battery from the machine. Release the trimmer head from grass. Allow the machine to cool down. Clean with compressed air or a soft brush. Contact your service agent. Troubleshooting the battery and/or the battery charger during charging. Battery LED display Green activate LED flashing. Error LED flashing Possible faults Low battery voltage. The battery is discharged. Temperature deviation. Error LED is lit Battery charger LED display Cell difference too much (1V). Possible faults Temperature deviation. Error LED flashing Over voltage. Error LED is lit Possible action Charge the battery. Charge the battery. Use the battery in surroundings where temperatures are between -10 °C and 40 °C. Contact your service agent. Possible action Use the battery charger only when the surrounding temperature is between 5 °C and 40 °C. Check that the mains voltage corresponds with that stated on the rating plate on the machine. Remove the battery from the battery charger. Contact your service agent. English - 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

English – 21
MAINTENANCE
Troubleshooting schedule
Keypad
Troubleshooting takes place from the keypad.
Troubleshooting the battery and/or the battery charger during charging.
Battery
Battery charger
Control panel
Possible faults
Possible action
Green activate LED flashing.
Low battery voltage.
Charging the battery
Error LED flashes.
The power trigger and the activate
button are pressed at the same
time.
Release the power trigger and the
machine is active.
Overload.
The trimmerhead is jammed.
Remove the battery from the
machine. Release the trimmer
head from grass.
Temperature deviation.
Allow the machine to cool down.
The machine does not start
Dirt in battery connectors.
Clean with compressed air or a soft
brush.
Error LED is lit with red light.
Service
Contact your service agent.
LED display
Possible faults
Possible action
Green activate LED flashing.
Low battery voltage.
Charge the battery.
Error LED flashing
The battery is discharged.
Charge the battery.
Temperature deviation.
Use the battery in surroundings
where temperatures are between -10
°
C and 40
°
C.
Error LED is lit
Cell difference too much (1V).
Contact your service agent.
LED display
Possible faults
Possible action
Error LED flashing
Temperature deviation.
Use the battery charger only when the
surrounding temperature is between 5
°
C and 40
°
C.
Over voltage.
Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.
Remove the battery from the battery
charger.
Error LED is lit
Contact your service agent.