Page 21 highlights
MAINTENANCE Troubleshooting schedule Keypad Troubleshooting takes place from the keypad. Control panel Green activate LED flashing. Error LED flashes. The machine does not start Error LED is lit with red light. Possible faults Low battery voltage. The power trigger and the activate button are pressed at the same time. Overload. Temperature deviation. Dirt in battery connectors. Service Possible action Charging the battery Release the power trigger and the machine is active. The trimmerhead is jammed. Remove the battery from the machine. Release the trimmer head from grass. Allow the machine to cool down. Clean with compressed air or a soft brush. Contact your service agent. Troubleshooting the battery and/or the battery charger during charging. Battery LED display Green activate LED flashing. Error LED flashing Possible faults Low battery voltage. The battery is discharged. Temperature deviation. Error LED is lit Battery charger LED display Cell difference too much (1V). Possible faults Temperature deviation. Error LED flashing Over voltage. Error LED is lit Possible action Charge the battery. Charge the battery. Use the battery in surroundings where temperatures are between -10 °C and 40 °C. Contact your service agent. Possible action Use the battery charger only when the surrounding temperature is between 5 °C and 40 °C. Check that the mains voltage corresponds with that stated on the rating plate on the machine. Remove the battery from the battery charger. Contact your service agent. English - 21