Connect an SSG to the antenna connector and set

Page 29 highlights

SOFTWARE ADJUSTMENTS-Continued ADJUSTMENT ADJUSTMENT CONDITION OPERATION S-METER 21 • Mode : FM • Push [8 SET] key. [S-M] • Connect an SSG to the antenna connector and set as (2510.1 MHz Level : 0.56 µV* (-112 dBm) FM mode) Frequency : 2510.1 MHz Modulation : ±1 kHz Deviation : ±3.5 kHz • Receiving (2510.1 MHz 22 • Mode : WFM • Push [8 SET] key. WFM mode) • Connect an SSG to the antenna connector and set as Level : 32 µV* (-77 dBm) Deviation : ±52.5 kHz • Receiving *This output level of a standard signal generator (SSG) is indicated as SSG's open circuit. 5 - 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

5 - 7
SOFTWARE ADJUSTMENTS
Continued
S-METER
[S-M]
(2510.1 MHz
FM mode)
(2510.1 MHz
WFM mode)
21
22
Mode
: FM
Connect an SSG to the antenna connector and set as
Level
: 0.56 μV* (
112 dBm)
Frequency
: 2510.1 MHz
Modulation
: ±1 kHz
Deviation
: ±3.5 kHz
Receiving
Mode
: WFM
Connect an SSG to the antenna connector and set as
Level
: 32 μV* (
77 dBm)
Deviation
: ±52.5 kHz
Receiving
Push
[8 SET]
key.
Push
[8 SET]
key.
ADJUSTMENT
ADJUSTMENT CONDITION
OPERATION
*This output level of a standard signal generator (SSG) is indicated as SSG