Page 27 highlights

5-3 TRANSMIT ADJUSTMENT (Continued) • DEVIATION ADJUSTMENTS (Continued) Select an adjustment item using / , and then set the adjustment value as specified using [DIAL]. ADJUSTMENT ADJUSTMENT ITEM OPERATION DV BALANCE -VHF[BAND LOW] [BAND CENTER] 1 1) Set the power supply voltage to 7.4 V. 2) Connect a modulation analyzer to the antenna connector through an attenuator, and then set it as; - HPF : OFF LPF : 20 kHz De-emphasis : OFF Detector : (P-P)/2 3) No audio signal is applied. 2 • While transmitting, adjust the deviation using [DIAL], and then push to store the adjustment value. 3 [BAND HIGH] -UHF[BAND LOW] 4 [DVR] 5 [BAND CENTER] 6 [BAND HIGH] 7 VALUE - Minimum deviation 5 - 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

5 - 9
5-3 TRANSMIT ADJUSTMENT (Continued)
• DEVIATION ADJUSTMENTS (Continued)
Select an adjustment item using
/
, and then set the adjustment value as specified using
[DIAL]
.
ADJUSTMENT
ADJUSTMENT
ITEM
OPERATION
VALUE
DV BALANCE
1
1) Set the power supply voltage to 7.4 V.
2)
Connect a modulation analyzer to the antenna connector through
an attenuator, and then set it as;
HPF
: OFF
LPF
: 20 kHz
De-emphasis : OFF
Detector
: (P-P)/2
3)
No audio signal is applied.
-VHF-
[BAND LOW]
[DVR]
2
While transmitting, adjust the deviation using
[DIAL]
, and then
push
to store the adjustment value.
Minimum
deviation
[BAND CENTER]
3
[BAND HIGH]
4
-UHF-
[BAND LOW]
5
[BAND CENTER]
6
[BAND HIGH]
7