Mounting requirements, from the floor to the top
View all Insignia NS-OTR17SS3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Mounting requirements • The space between the cabinets must be 30 in. (76.2 cm) wide. If the space between the cabinets is more than 30 in. (76.2 cm), you'll need filler material to fill the gap between the microwave and cabinets. • If the cabinet depth, including the cabinet doors, is more than 13 in. (33 cm), the unit must be spaced out from the wall using adequate materials capable of supporting 150 lbs. (68 kg) to allow for proper top vent air exhaust/intake. (See Figure 1) • If installing the microwave beneath smooth, flat cabinets, make sure that you leave enough space for the power cord clearance. • If you are going to vent your exhaust to the outside, see Exhaust requirements on page 7 for exhaust duct preparation. Figure 1 13 in. MAX. (33 cm) 16-1/2 in. (41.9 cm) 30 in. (76.2 cm) 2 in. (5.1 cm) 30 in. (76.2 cm) min. 66 in. (167.6 cm) or more from the floor to the top of the microwave 1/4 in. min. (6.35 mm) Clearance 6 www.insigniaproducts.com