Intel RES2SV240 Hardware User Guide - Page 27

SFF8087 to SFF8087 connector cable - motherboard

Page 27 highlights

Controller(or backplane) Connector PinOut Expander Connector Pin-Out Pin No B10 B11 B12 B13 B14 B15 B16 B17 B18 Signal GND SAS_A_SB_CTRL_TYPE GND SAS_TX_C_DP SAS_TX_C_DN GND SAS_TX_C_DP SAS_TX_C_DN GND Pin No A10 A11 A12 A13 A14 A15 A16 A17 A18 Signal SAS_A_SB4 SAS_A_SB5 GND SAS_RX_C_DP SAS_RX_C_DN GND SAS_RX_C_DP SAS_RX_C_DN GND Figure 8. SFF8087 to SFF8087 connector cable To successfully connect the expander card to supported RAID devices and backplanes, additional cables may be needed. They are not shipped with this expander card, but below introduction provides detailed pin-out specification, so that users would be able to find such cable from market. In server chassis non-expander backplane that has SGPIO connector on it, following cable is needed: SFF8087 to Four-port Internal Cable with one SGPIO Connector. Check the RAID controller/module and server backplane configuration details from http://www.intel.com/support/motherboards/server/ in order to get more details of whether necessary cables are included and how to configure the cabling. Additional cables may be needed depending on different types of initiator and target devices. Intel® RAID Expander Card RES2SV240 Hardware User's Guide 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

Intel® RAID Expander Card RES2SV240 Hardware User’s Guide
17
Figure 8. SFF8087 to SFF8087 connector cable
To successfully connect the expander card to supported RAID devices and backplanes,
additional cables may be needed. They are not shipped with this expander card, but below
introduction provides detailed pin-out specification, so that users would be able to find
such cable from market.
In server chassis non-expander backplane that has SGPIO connector on it, following cable
is needed: SFF8087 to Four-port Internal Cable with one SGPIO Connector. Check the
RAID controller/module and server backplane configuration details from
in order to get more details of whether
necessary cables are included and how to configure the cabling. Additional cables may be
needed depending on different types of initiator and target devices.
B10
GND
A10
SAS_A_SB4
B11
SAS_A_SB_CTRL_TYPE
A11
SAS_A_SB5
B12
GND
A12
GND
B13
SAS_TX_C_DP<
2
>
A13
SAS_RX_C_DP<
2
>
B14
SAS_TX_C_DN<
2
>
A14
SAS_RX_C_DN<
2
>
B15
GND
A15
GND
B16
SAS_TX_C_DP<
3
>
A16
SAS_RX_C_DP<
3
>
B17
SAS_TX_C_DN<
3
>
A17
SAS_RX_C_DN<
3
>
B18
GND
A18
GND
Controller(or backplane) Connector Pin-
Out
Expander Connector Pin-Out
Pin No
Signal
Pin No