Intel S1200BT Specification update - Page 15
The RPM of three fans on Intel® Server System R1304BTLSHBN may
View all Intel S1200BT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Monthly Specification Update Enterprise Platforms and Services Marketing Status Workaround The issue may be fixed in a future BIOS version. None 19. Keyboard does not work under EFI if USB flash disk is inserted/removed when TXT is enabled in BIOS Setup Problem Enable TXT function in BIOS and then insert or remove USB flash disk, keyboard may not work under EFI. Implication The user can not insert or remove USB flash disk if the user needs to use keyboard under EFI when TXT is enabled. Status Fixed in BIOS Revision 30. Workaround None 20. When using Hardware RAID controller, pressing "Ctrl+G" can not enter RAID configuration utility Problem If using hardware RAID controller, pressing "Ctrl+G" cannot enter RAID configuration utility. Implication The user can not configure hardware RAID controller using RAID configuration utility. Status This issue has been fixed in BIOS Rev.28. After updating to BIOS Rev.28, the user needs to load BIOS default setting. Workaround None 21. The RPM of three fans on Intel® Server System R1304BTLSHBN may drop to 0 sometimes after AC cycle Problem After AC power off and power on, the RPM of three fans on Intel® Server System may R1304BTLSHBN drop to 0. Implication This issue happens after 1000 AC cycles with R1304BTLSHBN. After this issue happens, an AC cycle will recover the system. Status Fixed in BMC Rev1.10. Workaround None 22. PCT reports "Processor Does Not Support Brand ID" 9