Page 18 highlights
Monthly Specification Update Enterprise Platforms and Services Marketing Implication Status Workaround The boot up time is too long. Fixed in BIOS Rev. 35. None. 30. Unable to get Server Management variables on BTP using SysCfg Problem Implication Server Management Settings cannot be configured using latest SysCfg Version 10 Build6 on S1200BTL. . The user can't change BMC setting by the latest syscfg tool on Intel® Server Board S1200BTL. Status Fixed in BIOS Rev. 35. Workaround None. 31. Function key can not work on KVM remote console on S1200BTL board Problem Function key can not work on KVM remote console on S1200BTL board. . Implication The user can't enter into BIOS setting from KVM remote console during server is booting up. Status Fixed in BIOS Rev.37. Workaround Enter BIOS setting to set the option "System Boot Timeout" from 0 to 3 seconds. 32. ME downgrade is not supported by IDA and OFU Problem IDA and OFU can not support ME downgrade. Implication IDA and OFU doesn't support ME downgrade from 02.02.00.036 or higher version to 02.00.09.032 or lower version. Status Will fix in the future IDA and OFU release. Workaround None 33. When updating BMC in IDA, IDA shows BMC Release version in Hex. E.g: 1.14 shown as 1.0e Problem IDA can not show BMC version in decimalization. Implication IDA only can show BMC release version in Hex when updating BMC by IDA tool. 12
![](/manual_guide/products/intel-s1200bt-specification-update-7d201c2/18.png)