Intel SC5299-E User Guide - Page 71

Replacing a Hot Swap Power Supply BRP configuration

Page 71 highlights

Hardware Installations and Upgrades Replacing a Hot Swap Power Supply (BRP configuration only) Warning: Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing of the power supply should be done only by technically qualified personnel. 1. Observe the safety and ESD precautions listed in Appendix A, "Safety Information". 2. Remove power cable from defective power supply. 3. Press up on green latch (see letter "A" in the following figure) while pulling on handle (see letter "B") to remove hot swap power supply from chassis. B A TP00856 Figure 66. Removing Hot Swap Power Supply Module from Chassis 4. Insert new hot swap power supply module. TP00854 Figure 67. Inserting Hot Swap Power Supply Module in Chassis 5. Connect power cable to replaced hot swap power supply. Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

Hardware Installations and Upgrades
Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide
53
Replacing a Hot Swap Power Supply (BRP configuration
only)
Warning:
Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are
present inside the power supply. There are no user-serviceable parts inside it; servicing of
the power supply should be done only by technically qualified personnel.
1.
Observe the safety and ESD precautions listed in
Appendix A, “Safety Information”
.
2.
Remove power cable from defective power supply.
3.
Press up on green latch (see letter “A” in the following figure) while pulling on handle
(see letter “B”) to remove hot swap power supply from chassis.
Figure 66.
Removing Hot Swap Power Supply Module from Chassis
4.
Insert new hot swap power supply module.
Figure 67.
Inserting Hot Swap Power Supply Module in Chassis
5.
Connect power cable to replaced hot swap power supply.
TP00856
A
B
TP00854