JVC DLA-HD10KU DLA-HD10K Owner's Manual (50 pages) - Page 46

Terminal Description continued, External control command table, Parameters used for the data format

Page 46 highlights

Terminal Description (continued) C Parameters used for the data format The following 3 types of parameters are used for command and response data: (1) Numeric value (2) ON/OFF (3) Special parameters Each parameter is as follows: (1) Numeric value A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters. The range that can be specified is from A8000HB to A7FFFHB (2) ON/OFF Shows the status (ON or OFF) of the unit, such as POWER and HIDE. Character Hex Meaning 0 30 OFF 1 31 ON (3) Special parameters Operation mode parameters Character Hex 0000 30h 30h 30h 30h 0001 30h 30h 30h 31h 0002 30h 30h 30h 32h 0004 30h 30h 30h 34h Meaning Standby mode Operate mode Cool down mode Emergency mode c External control command table Function Asking Command Operate mode ELSE Operate U0F ‫ן‬ ‫ן‬ HIDE U00 X ‫ן‬ Left/Right Reversal U17 X ‫ן‬ Top/Bottom U18 Inversion X ‫ן‬ Operation Mode Z03 X X Operation mode: Only Asking command is possible Data Type Numeric Value ON/OFF ‫ן‬ X ‫ן‬ X ‫ן‬ X ‫ן‬ X ‫ן‬ ‫ן‬ Special Data X 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

46
Terminal Description (continued)
C
Parameters used for the data format
The following 3 types of parameters are used for command and response data:
(1) Numeric value
(2) ON/OFF
(3) Special parameters
Each parameter is as follows:
(1) Numeric value
A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters.
The range that can be specified is from
A
8000H
B
to
A
7FFFH
B
(2) ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
(3) Special parameters
Operation mode parameters
c
External control command table
Operation mode: Only Asking command is possible
Character
Hex
Meaning
0
30
OFF
1
31
ON
Character
Hex
Meaning
0000
30h 30h 30h 30h
Standby mode
0001
30h 30h 30h 31h
Operate mode
0002
30h 30h 30h 32h
Cool down mode
0004
30h 30h 30h 34h
Emergency mode
Function
Command
Asking
Data Type
Operate mode
ELSE
Numeric Value
ON/OFF
Special Data
Operate
U0F
³
³
³
X
³
HIDE
U00
X
³
³
X
³
Left/Right Reversal
U17
X
³
³
X
³
Top/Bottom
Inversion
U18
X
³
³
X
³
Operation Mode
Z03
X
X
³
³
X