Terminal Description continued, External control command table, Parameters used for the data format
View all JVC DLA-HD10KU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Terminal Description (continued) C Parameters used for the data format The following 3 types of parameters are used for command and response data: (1) Numeric value (2) ON/OFF (3) Special parameters Each parameter is as follows: (1) Numeric value A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters. The range that can be specified is from A8000HB to A7FFFHB (2) ON/OFF Shows the status (ON or OFF) of the unit, such as POWER and HIDE. Character Hex Meaning 0 30 OFF 1 31 ON (3) Special parameters Operation mode parameters Character Hex 0000 30h 30h 30h 30h 0001 30h 30h 30h 31h 0002 30h 30h 30h 32h 0004 30h 30h 30h 34h Meaning Standby mode Operate mode Cool down mode Emergency mode c External control command table Function Asking Command Operate mode ELSE Operate U0F ן ן HIDE U00 X ן Left/Right Reversal U17 X ן Top/Bottom U18 Inversion X ן Operation Mode Z03 X X Operation mode: Only Asking command is possible Data Type Numeric Value ON/OFF ן X ן X ן X ן X ן ן Special Data X 46