2 CONTROLS AND CONNECTORS 2-13 FRReOarNPTaPnAeNl EL 1 23 4 MIC IN CAM SW ALARM ALARM COM SERIES/CLOCK OUT IN REC OUT WARNING COM ALARM TAPE /REC RESET END OUT OUT IN OUT REMOTE VIDEO AUDIO IN IN OUT OUT CAM SW ALARM ALARM COM SERIES/CLOCK OUT IN REC OUT WARNING COM ALARM TAPE /REC RESET END OUT OUT IN OUT 8 76 5 Connecting the wires to the terminals 8 button 1. Hold the button down and insert the wire over the top of the terminal. 2. Release the button to lock the wire in the terminal. 1 Power cable Connect the power plug to an AC 120 V, 50/60 Hz outlet. 2 [MIC IN] mic input connector Connect a microphone with 3.6-mm dia. plug. When signals are input from both the microphone connector and the audio input connector, audio signals are mixed and recorded. 3 [VIDEO IN] video input connector (BNC) Receives composite video signals from a connected camera or other video source. 4 [AUDIO IN] audio input connector (RCA) Receives audio signals from a connected audio source. 5 [AUDIO OUT] audio output connector (RCA) Outputs audio signals. 6 [VIDEO OUT] video output connector (BNC) Outputs composite video signals. Input camera signals (composite video signals) can still be output through this connector even when no power is supplied to the unit (Power-Off Video Throughput function). 7 [REMOTE] remote connector Connect the optional RM-G30U remote control. 8 [SERIES/CLOCK OUT] series recording signal/clock reset signal output terminal Outputs the series recording signals or clock reset signals. Select the output signal with the menu switch. • Series recording signal output When the menu switch is set to "SERIES", the series recording signal is output. • Connect to the other VCR series recording signal input terminal. When the tape being recorded in this unit ends, a signal is output from this terminal to the connected VCR. • Select the signal output timing with the menu switch (tape end, or 3 minutes or 6 minutes before the tape ends during 6H mode). • Clock reset signal output When the menu switch is set to "C.ADJ", the clock reset signal is output when the internal clock is at AM0:00 and PM0:00. When connected to the [CLOCK IN] terminal of another SR9168U, this unit's time can be synchronized with the time on the other VCR if the time difference is within ±30 seconds. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

9
CAM SW
OUT
ALARM
IN
COM
COM
ALARM
REC OUT
SERIES/CLOCK
ALARM
RESET
TAPE
END OUT
WARNING
/REC
OUT
IN
OUT
8
7
1
2
3
4
6
5
VIDEO
AUDIO
IN
IN
OUT
OUT
REMOTE
MIC
IN
CAM SW
OUT
ALARM
IN
COM
COM
ALARM
REC OUT
SERIES/CLOCK
ALARM
RESET
TAPE
END OUT
WARNING
/REC
OUT
IN
OUT
2-3
Rear Panel
2
CONTROLS AND CONNECTORS
1
Power cable
Connect the power plug to an AC 120 V, 50/60 Hz
outlet.
2
[MIC IN] mic input connector
Connect a microphone with 3.6-mm dia. plug.
When
signals are input from both the microphone connector
and the audio input connector, audio signals are mixed
and recorded.
3
[VIDEO IN] video input connector (BNC)
Receives composite video signals from a connected
camera or other video source.
4
[AUDIO IN] audio input connector (RCA)
Receives audio signals from a connected audio source.
5
[AUDIO OUT] audio output connector (RCA)
Outputs audio signals.
6
[VIDEO OUT] video output connector (BNC)
Outputs composite video signals.
Input camera signals
(composite video signals) can still be output through this
connector even when no power is supplied to the unit
(Power-Off Video Throughput function).
7
[REMOTE] remote connector
Connect the optional RM-G30U remote control.
8
[SERIES/CLOCK OUT] series recording signal/clock
reset signal output terminal
Outputs the series recording signals or clock reset
signals.
Select the output signal with the <TERMINAL SEL 1>
menu switch.
Series recording signal output
When the <TERMINAL SEL 1> menu switch is set to
“SERIES”, the series recording signal is output.
Connect to the other VCR series recording signal input
terminal.
When the tape being recorded in this unit
ends, a signal is output from this terminal to the
connected VCR.
Select the signal output timing with the <REC
REMAIN> menu switch (tape end, or 3 minutes or 6
minutes before the tape ends during 6H mode).
Clock reset signal output
When the <TERMINAL SEL 1> menu switch is set to
“C.ADJ”, the clock reset signal is output when the
internal clock is at AM0:00 and PM0:00.
When
connected to the [CLOCK IN] terminal of another SR-
9168U, this unit’s time can be synchronized with the
time on the other VCR if the time difference is within
±30 seconds.
Connecting the wires to the terminals
8
button
1.
Hold the button down
and insert the wire
over the
top of the
terminal.
2.
Release the button to
lock the wire in the
terminal.