JVC VN-E4U Instruction Manual - Page 18

[COM1, 2] Serial Port Terminals, 4-4 Alarm Input, Pin No., When RS-232C is selected, Function

Page 18 highlights

Preparation (continued) Ⅵ4-3 [COM1,2] Serial Port Terminals CONTROL 2CH COM1 SERVICE COM OUTPUT RS-232C RS-485 4CH COM2 10BASE Connect the device (camera, etc.) to be controlled to the serial port. Use the switch to switch between RS-232C and RS-485. ● Pin Layout Pin No. When RS-232C is selected Name Function When RS-485 is selected Name Function 1 (NC) (Not in use) RX+ + Receiving End 2 RXD Receive data RX - - Receiving End 3 TXD Send data TX - - Sending End 4 (NC) (Not in use) TX+ + Sending End 5 GND Grounding GND Grounding 6 (NC) (Not in use) (NC) (Not in use) 7 (NC) (Not in use) (NC) (Not in use) 8 (NC) (Not in use) (NC) (Not in use) 9 (NC) (Not in use) (NC) (Not in use) Ⅵ4-4 Alarm Input CONTROL ALARM SERVICE OUTPUT COM OUT 1 2 3 4 G INPUT PUSH RESET 10BASE-T/100BASE-TX DC 5V For connecting the sensor. This consists of 4 input and 1 ground terminals. Either Make or Break is selected depending on the setting, and sensors of the no-voltage A contact output (normally open), no-voltage B contact output (normally closed) or novoltage C contact output type may be used. Ⅵ4-5 Alarm Output COM1 COM2 A CONTROL SERVICE OUTPUT COM OUT 1 2 3 4 G I PUSH RESET 10BASE-T/100BASE-TX DC 5V The [OUT] and [COM] terminals form the make contact. Connect the device that is to be turned on during an alarm. Alarm output changes to break when the power of VN-E4 is turned off. Upon starting up VN-E4, the alarm output is restored to the previous state.(A pg. 54, A8. SpecificationsB) 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

18
Preparation
(continued)
±
4-3 [COM1,2] Serial Port Terminals
Connect the device (camera, etc.) to be controlled to the serial port. Use the switch to switch between RS-232C and RS-485.
Pin Layout
±
4-4 Alarm Input
For connecting the sensor. This consists of 4 input and 1 ground terminals. Either Make or Break is selected depending on the
setting, and sensors of the no-voltage A contact output (normally open), no-voltage B contact output (normally closed) or no-
voltage C contact output type may be used.
±
4-5 Alarm Output
The [OUT] and [COM] terminals form the make contact. Connect the device that is to be turned on during an alarm. Alarm output
changes to break when the power of VN-E4 is turned off. Upon starting up VN-E4, the alarm output is restored to the previous
state.(
A
pg. 54,
A
8. Specifications
B
)
Pin No.
When RS-232C is selected
When RS-485 is selected
Name
Function
Name
Function
1
(NC)
(Not in use)
RX+
+ Receiving End
2
RXD
Receive data
RX
-
-
Receiving End
3
TXD
Send data
TX
-
-
Sending End
4
(NC)
(Not in use)
TX+
+ Sending End
5
GND
Grounding
GND
Grounding
6
(NC)
(Not in use)
(NC)
(Not in use)
7
(NC)
(Not in use)
(NC)
(Not in use)
8
(NC)
(Not in use)
(NC)
(Not in use)
9
(NC)
(Not in use)
(NC)
(Not in use)
SERVICE
CONTROL
RS-485
RS-232C
OUTPUT
COM2
10BASE
2CH
4CH
COM
COM1
PUSH
ALARM
SERVICE
CONTROL
INPUT
OUTPUT
10BASE-T/100BASE-TX
COM OUT
1
2
3
4
G
DC 5V
RESET
PUSH
A
SERVICE
CONTROL
I
OUTPUT
COM2
10BASE-T/100BASE-TX
COM OUT
1
2
3
4
G
DC 5V
RESET
COM1