JVC VN-E4U Instruction Manual - Page 25

Alarm

Page 25 highlights

Settings (continued) Ⅵ5-4 Alarm Page This page is for setting actions when there is an alarm. Up to 10 actions may be set. This page can be used upon access via AadminB or AoperatorB. Press the AOKB button to enable the new settings upon changing. If the AOKB button is pressed upon entering an invalid value, a warning message will appear and entry will be denied. Press the ACancelB button to restore the invalid entry to the current value. A B C D A Action B 1st Trigger C Max. Interval D 2nd Trigger For specifying the type of action. Disable : Do not invoke action. Mail : Specify the mail address of the destination. An action number will be added to the mail subject, as shown in the following example. Alarm from VN-E4: No. 1 To attach a message to the mail, enter the message in AMail CommentB. Refer to A5-5 Alarm Environment PageB for mail environment settings. FTP : FTP the JPEG as specified in AInput SourceB. Refer to A5-5 Alarm Environment PageB for FTP environment settings. FTP can be set on only 1 action out of the 10 actions. TCP UDP : Send message entered in the ATCP/UDP CommentB field to the destinations specified in AIP AddressB and APort NumberB via ATCPB. : Send message entered in the ATCP/UDP CommentB field to the destinations specified in AIP AddressB and APort NumberB via AUDPB. Pin Output Make : Change alarm output to Make. Refer to A5-5 Alarm Environment PageB on parameter settings for alarm output. Pin Output Break: Change alarm output to Break. Refer to A5-5 Alarm Environment PageB on parameter settings for alarm output. For specifying the first trigger to invoke the action. Either alarm input (make), alarm input (break) or motion detect can be selected. Refer to A5-5 Alarm Environment PageB on parameter settings for alarm input. When the second trigger is turned off, the action will be invoked by only the first trigger. In addition, when motion detection is selected as the first trigger, AMax. IntervalB and A2nd TriggerB will not be available for selection, and only the first trigger will function. Valid only when the second trigger is specified. For specifying the maximum interval between the first and second triggers. Action will be invoked when second trigger occurs after first trigger within the maximum interval. For specifying the second trigger to invoke the action. Either alarm input (make) or alarm input (break) can be selected. Unlike the first trigger, motion detect is not available as a choice. Refer to A5-5 Alarm Environment PageB on parameter settings for alarm input. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

25
Settings
(continued)
±
5-4 Alarm Page
This page is for setting actions when there is an alarm. Up to 10 actions may be set.
This page can be used upon access via
A
admin
B
or
A
operator
B
. Press the
A
OK
B
button to enable the new settings upon changing. If
the
A
OK
B
button is pressed upon entering an invalid value, a warning message will appear and entry will be denied. Press the
A
Cancel
B
button to restore the invalid entry to the current value.
A
Action
For specifying the type of action.
Disable
: Do not invoke action.
Mail
:
Specify the mail address of the destination. An action number will be added to
the mail subject, as shown in the following example.
Alarm from VN-E4: No. 1
To attach a message to the mail, enter the message in
A
Mail Comment
B
.
Refer to
A
5-5 Alarm Environment Page
B
for mail environment settings.
FTP
: FTP the JPEG as specified in
A
Input Source
B
. Refer to
A
5-5 Alarm
Environment Page
B
for FTP environment settings. FTP can be set on only 1
action out of the 10 actions.
TCP
: Send message entered in the
A
TCP/UDP Comment
B
field to the destinations
specified in
A
IP Address
B
and
A
Port Number
B
via
A
TCP
B
.
UDP
: Send message entered in the
A
TCP/UDP Comment
B
field to the destinations
specified in
A
IP Address
B
and
A
Port Number
B
via
A
UDP
B
.
Pin Output Make : Change alarm output to Make. Refer to
A
5-5 Alarm Environment Page
B
on
parameter settings for alarm output.
Pin Output Break: Change alarm output to Break. Refer to
A
5-5 Alarm Environment Page
B
on
parameter settings for alarm output.
B
1st Trigger
For specifying the first trigger to invoke the action. Either alarm input (make), alarm input (break)
or motion detect can be selected. Refer to
A
5-5 Alarm Environment Page
B
on parameter settings
for alarm input. When the second trigger is turned off, the action will be invoked by only the first
trigger. In addition, when motion detection is selected as the first trigger,
A
Max. Interval
B
and
A
2nd Trigger
B
will not be available for selection, and only the first trigger will function.
C
Max. Interval
Valid only when the second trigger is specified. For specifying the maximum interval between the
first and second triggers. Action will be invoked when second trigger occurs after first trigger
within the maximum interval.
D
2nd Trigger
For specifying the second trigger to invoke the action. Either alarm input (make) or alarm input
(break) can be selected. Unlike the first trigger, motion detect is not available as a choice. Refer
to
A
5-5 Alarm Environment Page
B
on parameter settings for alarm input.
B
C
D