Jenn-Air JES1750FS Installation Instruction - Page 10
Electrical Requirements - Canada Only, Gas Supply Requirements
View all Jenn-Air JES1750FS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Electrical Requirements - Canada Only WARNING Gas Supply Requirements WARNING Electrical Shock Hazard Electrically ground range. Failure to do so can result in death, fire, or electrical shock. Be sure that the electrical connection and wire size are adequate and in conformance with the CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local codes and ordinances. A copy of the above code standards can be obtained from: Canadian Standards Association 178 Rexdale Blvd. Toronto, ON M9W 1R3 CANADA ■ Check with a qualified electrical installer if you are not sure the range is properly grounded. Range Rating* 120/240 Volts 8.8-16.5 kW 16.6-22.5 kW 120/208 Volts 7.8-12.5 kW 12.6-18.5 kW Specified Rating of Power Supply Cord Kit and Circuit Protection Amps Temp Rating 40 or 50 194°F (90°C) 50 194°F (90°C) *The NEC calculated load is less than the total connected load listed on the model/serial/rating plate. ■ When a 4-wire, single phase 240 volt, 60 Hz., AC only electrical supply is available, a 40-amp minimum circuit protection is required on 30" (76.2 cm) ranges, fused on both sides of the line. ■ A time-delay fuse or circuit breaker is recommended. ■ This range is equipped with a UL or CSA International Certified Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of range's final location. ■ Do not use an extension cord. ■ The wiring diagram is located on the back of the range or in a clear plastic bag. Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Observe all governing codes and ordinances. IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or CAN/ CGA B149 - latest edition. IMPORTANT: Leak testing of the range must be conducted according to the manufacturer's instructions. Type of Gas Natural Gas: ■ This range is factory-set for use with Natural gas. See "Gas Conversions" section. The model/serial/rating plate located on the oven frame behind the top right-hand side of the oven door has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier. LP Gas Conversion: Conversion must be done by a qualified service technician. No attempt shall be made to convert the appliance from the gas specified on the model/serial/rating plate for use with a different gas without consulting the serving gas supplier. See "Gas Conversions" section. Gas Supply Line ■ Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ½" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. N OTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. †®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. 10