Jenn-Air JES1750FS Installation Instruction - Page 4

Installation Requirements - model

Page 4 highlights

INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed ■ Tape measure ■ 5¹⁄2" hole saw (round ducting) ■ Phillips screwdriver ■ Saw for 3¹⁄4" x 10" rectangle vent ■ Flat-blade screwdriver ■ ¹⁄8" (3 mm) flatblade screwdriver ■ Level ■ Drill ■ Adjustable wrench ■ Slip joint pliers ■ Pipe wrench ■ 15⁄16" (2.4 cm) combination wrench ■ #2 square bit and driver ■ Flashlight ■ Masking tape ■ Pipe-joint compound resistant to natural and LP gases ■ 3⁄16" (4.8 mm) carbide-tipped masonry drill bit (for concrete/ ceramic floors) ■ Noncorrosive leak-detection solution ■ Sheet metal aluminum tape For LP/Natural Gas Conversions ■ ¹⁄8" (3.2 mm) drill bit (for wood floors) ■ Marker or pencil ■ ½" (13 mm) combination wrench ■ ¼" (6 mm) nut driver ■ 9⁄32" (7 mm) nut driver Parts Supplied Check that all parts are included. ■ LP/Natural gas conversion kit (dual fuel models only) ■ Blower mounting/venting template ■ Grease filter (packaged in place) ■ Oven racks (3) ■ Blower motor kit (under unit) ■ Blower cover kit (packed in cavity) ■ 10-32 hex nuts (attached to terminal block) (3) ■ Direct wire lugs (3) ■ #12 x 15⁄8" (4.1 cm) screws (for mounting anti-tip bracket) (2) ■ Anti-tip bracket (inside oven cavity) Anti-tip bracket must be securely mounted to the back wall or floor. Thickness of flooring may require longer screws to anchor bracket to subfloor. Longer screws are available from your local hardware store. Parts Needed ■ Use an approved vent cap for proper performance. If an alternate wall or roof cap is used, be certain the cap size is not reduced and that it has a backdraft damper. ■ After determining your vent installation, one of the following is needed: 5" (12.7 cm) Round surface wall cap damper - Order Part Number A405. 6" (15.2 cm) Round surface wall cap damper - Order Part Number A406. N OTE: If using 6" (15.2 cm) round venting, you will need a 5" (12.7 cm) to 6" (15.2 cm) round vent transition. 3¼" x 10" (8.3 x 25.4 cm) Surface wall cap damper - Order Part Number A403. To order, see the "Assistance or Service" section of the Use and Care Guide: - Metal ducting - Vent clamp - Aluminum foil tape Check local codes and consult gas supplier. Check existing gas supply and electrical supply. See the appropriate "Electrical Requirements" and "Gas Supply Requirements" sections. It is recommended that all electrical connections be made by a licensed, qualified electrical installer. Optional Parts To purchase these or any other accessories, please reference the "Accessories" section of the Use and Care Guide for contact information. ■ Side Trim Kits: 5⁄8" (1.7 cm) Black - Order Part Number W10675026 5⁄8" (1.7 cm) Stainless Steel - O rder Part Number W10675028 1¹⁄8" (2.9 cm) Black - Order Part Number W10731886 1¹⁄8" (2.9 cm) Stainless Steel - O rder Part Number W10731887 ■ Backsplash Kits: High 6" (15.2 cm) Black - Order Part Number W10655449 High 6" (15.2 cm) Stainless Steel - Order Part Number W10655450 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools Needed
Tape measure
Phillips
screwdriver
Flat-blade
screwdriver
¹⁄
8
" (3 mm) flat-
blade screwdriver
Level
Drill
Adjustable wrench
Slip joint pliers
Pipe wrench
15
16
" (2.4 cm)
combination
wrench
¹⁄
8
" (3.2 mm) drill
bit (for wood
floors)
Marker or pencil
5¹⁄
2
" hole saw (round ducting)
Saw for 3¹⁄
4
" x 10" rectangle
vent
#2 square bit and driver
Flashlight
Masking tape
Pipe-joint compound resistant
to natural and LP gases
3
16
" (4.8 mm) carbide-tipped
masonry drill bit (for concrete/
ceramic floors)
Noncorrosive leak-detection
solution
Sheet metal aluminum tape
For LP/Natural Gas Conversions
½" (13 mm) combination
wrench
¼" (6 mm) nut driver
9
32
" (7 mm) nut driver
Parts Supplied
Check that all parts are included.
LP/Natural gas conversion kit (dual fuel models only)
Blower mounting/venting template
Grease filter (packaged in place)
Oven racks (3)
Blower motor kit (under unit)
Blower cover kit (packed in cavity)
10-32 hex nuts (attached to terminal block) (3)
Direct wire lugs (3)
#12 x 1
5
8
" (4.1 cm) screws (for mounting anti-tip bracket) (2)
Anti-tip bracket (inside oven cavity)
Anti-tip bracket must be securely mounted to the back wall
or floor. Thickness of flooring may require longer screws
to anchor bracket to subfloor. Longer screws are available
from your local hardware store.
Parts Needed
Use an approved vent cap for proper performance. If an
alternate wall or roof cap is used, be certain the cap size
is not reduced and that it has a backdraft damper.
After determining your vent installation, one of the following
is needed:
5" (12.7 cm) Round surface wall cap damper –
Order Part Number A405.
6" (15.2 cm) Round surface wall cap damper –
Order Part Number A406.
NOTE:
If using 6" (15.2 cm) round venting, you will need
a 5" (12.7 cm) to 6" (15.2 cm) round vent transition.
3¼" x 10" (8.3 x 25.4 cm) Surface wall cap damper –
Order Part Number A403.
To order, see the “Assistance or Service” section of the Use and
Care Guide:
– Metal ducting
– Vent clamp
– Aluminum foil tape
Check local codes and consult gas supplier. Check existing
gas supply and electrical supply. See the appropriate “Electrical
Requirements” and “Gas Supply Requirements” sections.
It is recommended that all electrical connections be made by
a licensed, qualified electrical installer.
Optional Parts
To purchase these or any other accessories, please reference
the “Accessories” section of the Use and Care Guide for
contact information.
Side Trim Kits:
5
8
" (1.7 cm) Black – Order Part Number W10675026
5
8
" (1.7 cm) Stainless Steel – Order Part Number
W10675028
1¹⁄
8
" (2.9 cm) Black – Order Part Number W10731886
1¹⁄
8
" (2.9 cm) Stainless Steel – Order Part Number
W10731887
Backsplash Kits:
High 6" (15.2 cm) Black – Order Part Number W10655449
High 6" (15.2 cm) Stainless Steel – Order Part Number
W10655450