Kenmore 2718 Use and Care Guide - Page 4
Do Notinstall - parts
View all Kenmore 2718 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
PRE-INSTALLATION REQUIREMENTS Tools Required for Installation: I. 1/4 in. nut driver 2. 3/8 in. socket with ratchet. 3. 3/8 in. open end wrench. 4. 7/16 in. socket with ratchet. 5. 9/16 in. open end wrench. 6. Channel-lock adjustable pliers. 7. Carpenter's level. DRAIN REQUIREMENTS Models equipped with drain pump: I. Drain MUST be capable of eliminating 17 gals (64.3 L) per minute. 2. A standpipe diameter of 1-1/4 in. (3.18 cm) minimum. 3. The standpipe height above the floor should be: ELECTRICAL REQUIREMENTS CIRCUIT-Individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker. POWER SUPPLY- 2 wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current. NOTE:The use of this washer with power created by gas powered generators, solar powered generators, wind powered generators or and other generator other than the local utility company is not recommended. OUTLETRECEPTACLE- Properly grounded 3-prong receptacle to be located so the power supply cord isaccessible when the washer is in an installed position. NOTE: GFI (Ground Fault Interrupter) receptacle is not required. 96 in. (244 cm) Max. 24 in. (61 cm) Mino __ .-- _ BACK .._..---- GROUNDING REQUIREMENTS Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt asto whether the appliance is properly grounded. 1. The washer MUST be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current. 2. Since your washer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUSTbe plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances or in the absence of local codes, with the National Electrical Codes, ANSI/NFPA 70 (latest edition). If in doubt, call a licensed electrician. NOTE: Drain hose attached to the washer can reach a 58 in. (147 cm) high standpipe. For higher standpipe use hose P/N 134592701, available from an authorized parts distributor. If drain is less than 24 in. (61 cm), install a siphon break kit, available at your local hardware store. Models equipped with gravity drain: 1. FloordrainMUSTbecapableof per minute. eliminating 17gals(64.3 L) 2. Floor drain diameter must be at least 1/2 inch larger than drain hose. LOCATION OF YOUR WASHER DO NOTINSTALL YOUR WASHER: I. In an area exposed to dripping water or outside weather conditions. The ambient temperature should never be below 60 degrees F(15.6 degrees C) for proper washer operation. 2. In an area where it will come in contact with curtains or drapes. DO NOTcut off or alter the grounding prong on the power supply 3. In an area (garage or garage-type building) where gasoline cord. In situations where a two-slot receptacle is present, it is the of other flammables are kept or stored (including owner's responsibility to have a licensed electrician replace it automobiles). with a properly grounded three prong grounding type 4. On carpet. Floor MUST be solid with a maximum slope of receptacle. I/2 in. per foot (1.27 cm per 30.5 cm). To ensure vibration or movement does not occur, reinforcement of the floor may WATER SUPPLY REQUIREMENTS be necessary. Hot and cold water faucets MUST be installed within 42 inches IMPORTANT MINIMUM INSTALLATION CLEARANCES (107 cm) of your washer's water inlet. The faucets MUST be 3/4 When installed in alcove: Sides, Rear, Top = 0 in (0 cm). When installed in closet: Sides, Rear, Top = 0 in (0 cm), inch (1.9 cm) garden hose type so inlet hoses can be connected. Water pressure MUSTbe between 10 and 120 pounds per square inch (maximum unbalance pressure, hot vs. cold, 10 psi.) Your water department can advise you of your water pressure. Front = 1 in (2.54 cm). Closet door ventilation openings required: 2 (387 cm 2)- 3 in (7.6 cm) from top and bottom 4 louvers each of door. 60 in2