Kenmore 2718 Use and Care Guide - Page 4

Do Notinstall - parts

Page 4 highlights

PRE-INSTALLATION REQUIREMENTS Tools Required for Installation: I. 1/4 in. nut driver 2. 3/8 in. socket with ratchet. 3. 3/8 in. open end wrench. 4. 7/16 in. socket with ratchet. 5. 9/16 in. open end wrench. 6. Channel-lock adjustable pliers. 7. Carpenter's level. DRAIN REQUIREMENTS Models equipped with drain pump: I. Drain MUST be capable of eliminating 17 gals (64.3 L) per minute. 2. A standpipe diameter of 1-1/4 in. (3.18 cm) minimum. 3. The standpipe height above the floor should be: ELECTRICAL REQUIREMENTS CIRCUIT-Individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker. POWER SUPPLY- 2 wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current. NOTE:The use of this washer with power created by gas powered generators, solar powered generators, wind powered generators or and other generator other than the local utility company is not recommended. OUTLETRECEPTACLE- Properly grounded 3-prong receptacle to be located so the power supply cord isaccessible when the washer is in an installed position. NOTE: GFI (Ground Fault Interrupter) receptacle is not required. 96 in. (244 cm) Max. 24 in. (61 cm) Mino __ .-- _ BACK .._..---- GROUNDING REQUIREMENTS Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt asto whether the appliance is properly grounded. 1. The washer MUST be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current. 2. Since your washer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUSTbe plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances or in the absence of local codes, with the National Electrical Codes, ANSI/NFPA 70 (latest edition). If in doubt, call a licensed electrician. NOTE: Drain hose attached to the washer can reach a 58 in. (147 cm) high standpipe. For higher standpipe use hose P/N 134592701, available from an authorized parts distributor. If drain is less than 24 in. (61 cm), install a siphon break kit, available at your local hardware store. Models equipped with gravity drain: 1. FloordrainMUSTbecapableof per minute. eliminating 17gals(64.3 L) 2. Floor drain diameter must be at least 1/2 inch larger than drain hose. LOCATION OF YOUR WASHER DO NOTINSTALL YOUR WASHER: I. In an area exposed to dripping water or outside weather conditions. The ambient temperature should never be below 60 degrees F(15.6 degrees C) for proper washer operation. 2. In an area where it will come in contact with curtains or drapes. DO NOTcut off or alter the grounding prong on the power supply 3. In an area (garage or garage-type building) where gasoline cord. In situations where a two-slot receptacle is present, it is the of other flammables are kept or stored (including owner's responsibility to have a licensed electrician replace it automobiles). with a properly grounded three prong grounding type 4. On carpet. Floor MUST be solid with a maximum slope of receptacle. I/2 in. per foot (1.27 cm per 30.5 cm). To ensure vibration or movement does not occur, reinforcement of the floor may WATER SUPPLY REQUIREMENTS be necessary. Hot and cold water faucets MUST be installed within 42 inches IMPORTANT MINIMUM INSTALLATION CLEARANCES (107 cm) of your washer's water inlet. The faucets MUST be 3/4 When installed in alcove: Sides, Rear, Top = 0 in (0 cm). When installed in closet: Sides, Rear, Top = 0 in (0 cm), inch (1.9 cm) garden hose type so inlet hoses can be connected. Water pressure MUSTbe between 10 and 120 pounds per square inch (maximum unbalance pressure, hot vs. cold, 10 psi.) Your water department can advise you of your water pressure. Front = 1 in (2.54 cm). Closet door ventilation openings required: 2 (387 cm 2)- 3 in (7.6 cm) from top and bottom 4 louvers each of door. 60 in2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

PRE-INSTALLATION
REQUIREMENTS
Tools Required
for
Installation:
I.
1/4 in. nut driver
2. 3/8 in. socket with
ratchet.
3. 3/8 in. open end wrench.
4. 7/16 in. socket with
ratchet.
5. 9/16 in. open end wrench.
6. Channel-lock
adjustable
pliers.
7. Carpenter's
level.
ELECTRICAL
REQUIREMENTS
CIRCUIT-Individual,
properly polarized and grounded
15 amp.
branch circuit fused with 15 amp. time delay fuse or circuit breaker.
POWER SUPPLY-
2 wire, with ground, 120 volt, single phase, 60
Hz, Alternating
Current. NOTE:The use of this washer with power
created by gas powered generators, solar powered generators,
wind powered generators or and other generator other than the
local utility company is not recommended.
OUTLETRECEPTACLE-
Properly grounded 3-prong receptacle to
be located so the power supply cord isaccessible when the washer
is in an installed position. NOTE: GFI (Ground Fault Interrupter)
receptacle is not required.
DRAIN
REQUIREMENTS
Models equipped with drain pump:
I.
Drain
MUST
be capable of eliminating
17 gals (64.3 L) per
minute.
2.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3.
The standpipe height above the floor
should be:
__
BACK
.--
_
.._..----
96 in.
(244
cm)
Max.
24 in.
(61 cm)
Mino
GROUNDING
REQUIREMENTS
Improper connection of the equipment grounding
conductor
can result in a risk of electrical shock.
Check
with a
licensed electrician if you are in doubt asto whether the appliance
is properly grounded.
1.
The washer
MUST
be grounded. In the event of malfunction
or breakdown,
grounding
will
reduce the risk of electrical
shock by a path of least resistance for electrical current.
2.
Since your washer is equipped
with
a power
supply cord
having an equipment-grounding
conductor and a grounding
plug, the plug
MUSTbe
plugged into an appropriate, copper
wired
receptacle that is properly installed and grounded
in
accordance with
all local codes and ordinances
or in the
absence of local codes, with the National Electrical
Codes,
ANSI/NFPA 70 (latest edition).
If in doubt,
call a licensed
electrician.
DO NOTcut
off or alter the grounding prong on the power supply
cord. In situations where a two-slot
receptacle is present, it is the
owner's
responsibility
to
have a licensed electrician
replace it
with
a
properly
grounded
three
prong
grounding
type
receptacle.
WATER
SUPPLY REQUIREMENTS
Hot and cold water faucets
MUST
be installed within 42 inches
(107 cm) of your washer's water inlet. The faucets
MUST
be 3/4
inch (1.9 cm) garden hose type so inlet hoses can be connected.
Water pressure
MUSTbe
between 10 and 120 pounds per square
inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your
water department
can advise you of your water pressure.
NOTE:
Drain hose attached to the washer can reach a 58 in. (147 cm)
high standpipe. For higher standpipe use hose P/N 134592701,
available from an authorized
parts distributor.
If drain
is less
than 24 in. (61 cm), install a siphon break kit, available at your
local hardware store.
Models equipped with gravity drain:
1.
FloordrainMUSTbecapableof
eliminating
17gals(64.3
L)
per minute.
2.
Floor drain diameter
must be at least 1/2 inch larger than
drain hose.
LOCATION
OF
YOUR
WASHER
DO NOTINSTALL
YOUR WASHER:
I.
In an area exposed to
dripping
water
or outside weather
conditions. The ambient temperature should never be below
60 degrees F(15.6 degrees C) for proper washer operation.
2.
In an area where
it will
come in contact
with
curtains or
drapes.
3.
In an area (garage or garage-type building) where gasoline
of
other
flammables
are
kept
or
stored
(including
automobiles).
4.
On carpet. Floor
MUST
be solid with
a maximum
slope of
I/2 in. per foot (1.27 cm per 30.5 cm). To ensure vibration or
movement
does not occur, reinforcement
of the floor
may
be necessary.
IMPORTANT
MINIMUM
INSTALLATION
CLEARANCES
When installed in alcove: Sides, Rear,Top = 0 in (0 cm).
When installed in closet: Sides, Rear, Top = 0 in (0 cm),
Front = 1 in (2.54 cm).
Closet door ventilation
openings required:
2 louvers each 60 in2
(387 cm2)- 3 in (7.6 cm) from top and bottom of door.
4