Kenmore 4280 Installation Instructions - Page 1

Kenmore 4280 - Elite 30 in. Electric Induction Cooktop Manual

Page 1 highlights

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUAUNED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not store or use gasotine or other flammabte vapors and tiquids in the vicinity of this or any other appliance. IMPORTANT INSTALLATION INFORMATION All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only ele(tri(al supply with ground. Minimum distance between cooktop and overhead cabinetry is 30" (76.2 (m). * 30" (76.2 cm) rain. for unprotected cabinet and 24" (6! cm) rain. for cabinet with protected bottom surface. Cooktop Dimensions 30" Min, * (76,2 cm) ** Do not obstruct these areas. D Cooktop Cutout Dimensions C Air exhaust* * --I Fresh air intake** 4" X 8" (I 0.2 cm x 20.3 cm) opening to route armored (:able Figure 1 All dimensions are stated in inches and (cm). Allow 2" (5 cm) space below the armored cable opening to clear the electric (:able and allow space for installation of tile junction box on the wall at the back of the cooktop. Printed in United States P/N 318201429 (0604) Rev.C English - pages I-6 Espaflol - pages 7_12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

INSTALLATION
AND
SERVICE MUST
BE PERFORMED
BY A QUAUNED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL
ELECTRICAL
INSPECTOR'S
USE.
READ
AND
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasotine
or other
flammabte
vapors
and tiquids
in
the vicinity
of this or any other
appliance.
IMPORTANT INSTALLATION INFORMATION
All electric cooktops run off a single phase, three-wire
or four-wire cable, 240/208 volt, 60 hertz, AC only
ele(tri(al supply with ground.
Minimum
distance between cooktop and overhead cabinetry is 30" (76.2 (m).
Cooktop Dimensions
30"
Min, *
(76,2 cm)
* 30" (76.2 cm) rain. for
unprotected cabinet and
24" (6!
cm) rain. for cabinet
with protected bottom surface.
**
Do not obstruct
these areas.
Cooktop Cutout Dimensions
D
Air exhaust* *
--I
C
Fresh air intake**
4" X 8" (I 0.2 cm x 20.3 cm)
opening to route armored
(:able
Figure
1
All dimensions are stated in inches and (cm).
Allow 2" (5 cm) space below the armored cable opening to clear the electric (:able and
allow space for installation of tile junction
box on the wall at the back of the cooktop.
Printed in United States
P/N318201429
(0604) Rev.C
English - pages I-6
Espaflol - pages 7_12