Kenmore 6962 Installation Instructions - Page 2
Kenmore 6962 - 600 7.0 cu. Ft. Capacity Electric Dryer Manual
UPC - 883049149578
View all Kenmore 6962 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
INSTALLATION INSTRUCTIONS • • A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements." A sturdy floor to support the total weight (dryer and load) of 200 Ib (90.7 kg). The combined weight of a companion appliance should also be considered. A level floor with a maximum slope of 1 in. (2.5 cm) under entire dryer. (If slope is greater than 1 in. [2.5 cm], install Extended Dryer Feet Kit, Part No. 279810.) Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level. Check that you have everything necessary for correct installation. Proper installation is your responsibility. Flat-blade screwdriver Adjustable wrench that opens to 1 in. (2.5 cm) or hex-head socket wrench (for adjusting dryer feet) Level #2 Phillips screwdriver Vent clamps Tin snips(new installations) Safety glasses Caulking gun and compound (for installing new exhaust vent) Gloves Wire stripper (direct wire installations) vent • Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended. Install the dryer where it is protected from water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. Installation Clearances Parts supplied: Remove parts package from dryer drum. Check that all parts were included. The location must be large enough to allow the dryer door to open fully. Dryer Dimensions 4 leveling legs Parts needed: Check local codes. Check existing electrical supply and venting and see "Electrical Requirements" and "Venting Requirements" before purchasing parts. Mobile home installations require metal exhaust system hardware available for purchase from your local Sears store or Sears Service Center. For further information call 1-8OO-4-MY-HOME ® (1-800-469-4663}. * 291/4" (743 cm) * Most installations require a minimum 51/2in. (14 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements." Minimum installation spacing for recessed area or closet installation The dimensions allowed. • Explosion Hazard such as • • shown following are for the minimum spacing Additional spacing should be considered for ease of installation and servicing. Additional clearances might be required for wall, door and floor moldings. Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer. For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. Keep fBammabBe materiaBs and vapors, gasoline, away from dryer. Place dryer at least 18 inches (46 cm) above the floor for a garage instalation. Failure to do so can resumt in death, explosion, or fire. You will need • • A location that allows for proper exhaust installation. See "Venting Requirements." A separate 30 amp circuit.