Kenmore 7972 Installation Instructions - Page 4
Rough-in, Dimensions - appliances
UPC - 883049200989
View all Kenmore 7972 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
GAS SUPPLYREQUIREMENTS ROUGH-IN DIMENSIONS 1. Installation MUST conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 edition) or in Canada, the current AN/CGA B149. 2.The gas supply line should be of 1/2 inch (1.27 cm) pipe. (latest 3. If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic-coated brass. 4. The gas supply line MUST have an individual shutoff valve. 5. A 1/8 inch (0.32 cm) N. R T. plugged tapping, accessible for test gage connection, MUST be installed immediately upstream of the gas supply connection to the dryen 6.The dryer and its individual shutoff valve MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa). 7.The dryer MUSTbe isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa). 16 I/4 IN. (41.27 CM) 25 ¼IN. i (64.13 CM) 2½IN. (6.3SCM) 1 7/8 IN. _\\\\\\\ [_ (4.76 CM) LOCATION OF YOUR LAUNDRY CENTER DO NOT INSTALL YOUR LAUNDRY CENTER: 1.In an area exposed to dripping conditions. water or outside weather 2. In an area where it will come in contact with curtains or drapes. 3. On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm). INSTALLATION IN RECESSOR CLOSET 36 1!161N. (91.60 CM) 4 13/16 iN. (12.22 CM) ( + 11 7116 IN. (29.5 CM) 1.A laundry bathroom, exhausted center installed in a bedroom, recess or closet, MUST be outdoors. 2. No other fuel burning appliance shall be installed in the same closet as the Gas laundry centen 3. Your laundry center needs the space around it for proper ventilation. DO NOT INSTALL YOUR LAUNDRY CENTER IN A CLOSET WITH A SOLID DOOR. 60 SQ. IN. (387.1 SQ. CM) 60 SQ. IN. (387.1 SQ. CM) 30 13/16 IN. (78.26 CM) 4. A minimum of 120 square inches (774.2 square cm) of opening, Closet Door equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable. 5.The following illustrations show minimum clearance dimensions and air openings installation. for proper operation in a recess or closet 751/2(N. (191.77 CM) 54 5/16 IN. (137.95 CM) 43 IN. (109.22 CM) 12 I/2 IN._ 9 3/8 IN. (31.75 CM_ (23.81 C_4) VENT_.._ / -1_\ _,_ f--GAS SUPPLY PIPE (REAR) s 1/4mN. ELECTRICAL CONNECTION © WATERINLETS _2_ (REAR) _13.33 CM) 1 43 IN. /(109.22 CM) 411/4IN I (104.77 CM) 29 7116 IN ._,_ (REAR) (74.77 CM) \J 3%1N. _:---(9.52 CM) ,m_ _ DRAIN OUTLET "! 27 IN. (68.58CM)