Code ANSI/NFPA No, 70-latest edition--andlocalelectrical

Page 3 highlights

B. Drill Pilot Holes and Fasten Bracket- Drilla 1/8" pilot hole where screws ere to be located, If bracket is to be mountedto the wall, drillpilotholeat an approximate20 ° downwardangle, If bracket isto be mountedto masonry or ceramic floors,drilla 5/32" pilothole 1-3/4"deep. The screws provided may be used in wood or concrete material, Use a 5/16" nut-driveror flat head screwdriver to secure the bracket in place. FASTEN BRACKET (W_LLORF1-OOMROUNTING) "--_1 E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

B.
Drill Pilot Holes and Fasten Bracket-
Drilla 1/8" pilot
hole where screws ere to be located, If bracket is to be
mountedto the wall, drillpilothole
at
anapproximate20°
downwardangle, If bracket isto be mountedto masonry
orceramicfloors,drill
a
5/32" pilothole 1-3/4"deep. The
screws provided
may
be used in wood or concrete
material, Use a 5/16" nut-driveror flat head screwdriver
to secure the bracket in place.
FASTEN
BRACKET
(W_LLORF1-OOR
MOUNTING)
"--_1
E<'--1-1/4"
Max.
Wall
Mount
,
'
................
lr
....
I
Floor Mount
.___Jr_
L-Anti-Tip
Bracket
FASTEN
BRACKET
(FLOORMOUNTINGONLY}
-+1
Leveling Leg
--
1-1/4"
2.
Electrical
Connection
Requirements
Thisappliancemustbeproperlyinstalledandgroundedbya
qualifiedtechnicianinaccordancewiththeNationalElectrical
Code ANSI/NFPA No, 70-latest edition--andlocalelectrical
code requirements.
This appliance may be connected by means of permanent
"Hard Wiring" or "Power Supply Cord Kit."
When
hard
wiring, do
not
leave
excess
wire
in range
compartment.
Excess wire in the range compartment may
not
allow
the access cover to be replaced properly, and could
create a potential
electrical
hazard if wires become pinched.
Connect only as instructed under'WIRING INSTRUCTIONS"
in section 4A or 4B. When using flexible conduit or range
cable use flex connector or range cable strain relief.
NOTE:
Only
use copperwire
in
connection
to terminal block.
Floor
Mount
J
_
Bracket
C.
Level and Position Range
-
Level range by adjusting
the (4) leveling legs with a wrench. Note: A minimum
clearance of 1/8" is required between the bottomof the
range and the leveling leg to allow room
for
the bracket.
Use a spiritlevelto check youradjustments. Slide range
back
into
position.Visuallycheckthatrearlevelinglegis
insertedintoand
fully
securedbytheAnti-TipBracketby
removinglowerpanelorstoragedrawer.Formodelswith
a warmer drawer or broiler compartment, grasp the top
rear edge of the range and carefully attempt to tilt it
forward.