Location Requirements The refrigerator can be recessed in an opening between cabinets or installed at the end of a cabinet run using a side panel to enclose the refrigerator. ■ A grounded 3 prong electrical outlet should be placed within 4" (10.2 cm) of the right side cabinets or end panel. See "Electrical Requirements" for additional information. WARNING ■ The water shutoff should be located in the base cabinet on either side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor or the back wall. See "Water Supply Requirements" for more specific information. Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from refrigerator. Failure to do so can result in death, explosion, or fire. IMPORTANT: ■ Observe all governing codes and ordinances. ■ It is recommended that you do not install the refrigerator near an oven, radiator, or other heat source. ■ Do not install in a location where the temperature will fall below 55°F (13°C). ■ Floor must support the refrigerator weight, more than 600 lbs (272 kg), door panels and contents of the refrigerator. ■ Ceiling height must allow for side tipping radius. See "Tipping Radius." ■ Location should permit door to open fully. See "Door Swing Dimensions." ■ Location must permit top grille removal. See "Opening Dimensions." Opening Dimensions ■ To avoid tipping during use, the solid soffit must be within 1" (2.5 cm) maximum above the refrigerator. If the solid soffit is higher than 1" (2.5 cm) or one is not available, then the refrigerator must be braced. If anti-tip boards are needed, they must be installed to the rear wall studs so that the bottom of the anti-tip board is 84" (213.4 cm) from the floor. See "Install Anti-Tip Boards" for more information. NOTES: ■ A clearance of ¹⁄₂" (1.3 cm) must be maintained above the top grille in order for the top grille to be removed. ■ Do not remove the foam gasket on top of the compressor cover unless removal is necessary to fit the unit under a soffit. Removal of the gasket will cause loss in cooling efficiency. ■ If installing under a solid soffit, after installation raise the leveling legs so that the gasket is pressed snugly against the soffit. A B ¹⁄₂" (1,3 cm) B Dimension 84" (213.4 cm) to bottom of solid soffit 77" (196 cm) A Width (see chart following) 6" (15.2 cm) 1" 6" (2.54 cm) (15.2 cm) 24" (60.96 cm) min. 6" (15.2 cm) Model 36 42 Width A Width A for (as shown Overlay Models above) (as shown above) 35¹⁄₂" to 35³⁄₄" 35³⁄₄" to 36" (90.2 cm to (90.8 cm to 91.4 cm) 90.8 cm) 41¹⁄₂" to 41³⁄₄" 41³⁄₄" to 42" (105.4 cm to (106 cm to 106.7 cm) 106 cm) Dimension B (as shown above) 4" (10.2 cm) 7¹⁄₂" (19 cm) NOTE: Flooring under refrigerator must be at same level as the room. A. Gasket B. Compressor cover 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

6
Location Requirements
The refrigerator can be recessed in an opening between cabinets
or installed at the end of a cabinet run using a side panel to
enclose the refrigerator.
IMPORTANT:
Observe all governing codes and ordinances.
It is recommended that you do not install the refrigerator near
an oven, radiator, or other heat source.
Do not install in a location where the temperature will fall
below 55°F (13°C).
Floor must support the refrigerator weight, more than 600 lbs
(272 kg), door panels and contents of the refrigerator.
Ceiling height must allow for side tipping radius. See “Tipping
Radius.”
Location should permit door to open fully. See “Door Swing
Dimensions.”
Location must permit top grille removal. See “Opening
Dimensions.”
Opening Dimensions
To avoid tipping during use, the solid soffit must be within 1"
(2.5 cm) maximum above the refrigerator. If the solid soffit is
higher than 1" (2.5 cm) or one is not available, then the
refrigerator must be braced.
If anti-tip boards are needed, they must be installed to the rear
wall studs so that the bottom of the anti-tip board is 84"
(213.4 cm) from the floor. See “Install Anti-Tip Boards” for
more information.
NOTES:
A clearance of
¹⁄₂
" (1.3 cm) must be maintained above the
top grille in order for the top grille to be removed.
Do not remove the foam gasket on top of the compressor
cover unless removal is necessary to fit the unit under a
soffit. Removal of the gasket will cause loss in cooling
efficiency.
If installing under a solid soffit, after installation raise the
leveling legs so that the gasket is pressed snugly against
the soffit.
A grounded 3 prong electrical outlet should be placed within
4" (10.2 cm) of the right side cabinets or end panel. See
“Electrical Requirements” for additional information.
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor or the
back wall. See “Water Supply Requirements” for more specific
information.
NOTE:
Flooring under refrigerator must be at same level as the
room.
A. Gasket
B. Compressor cover
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
¹⁄₂
"
(1,3 cm)
B
A
Model
Width A
(as shown
above)
Width A for
Overlay Models
(as shown above)
Dimension B
(as shown
above)
36
35
¹⁄₂
" to 35
³⁄₄
"
(90.2 cm to
90.8 cm)
35
³⁄₄
" to 36"
(90.8 cm to 91.4 cm)
4"
(10.2 cm)
42
41
¹⁄₂
" to 41
³⁄₄
"
(105.4 cm to
106 cm)
41
³⁄₄
" to 42"
(106 cm to 106.7 cm)
7
¹⁄₂
" (19 cm)
6"
(15.2 cm)
24"
(60.96 cm) min.
1"
(2.54 cm)
77"
(196 cm)
6"
(15.2 cm)
6"
(15.2 cm)
A
Width
(see chart following)
B
Dimension
84" (213.4 cm)
to bottom of solid soffit