KitchenAid KECD867XSS Installation Guide - Page 3

Installation Requirements - 36

Page 3 highlights

INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed ■ Grounded electrical supply is required. See "Electrical Requirements" section. ■ If cabinet has drawers, drawers will need to be removed and drawer fronts installed on front of cabinet. IMPORTANT: An under-counter built-in oven cannot be installed under this product. ■ Tape measure ■ Flat-blade screwdriver ■ Phillips head screwdriver ■ Drill ■ Level ■ 6" socket extension ■ Marker or pencil ■ Pliers ■ ¼" drill bit ■ Jigsaw ■ Ratchet with ³⁄₈"socket Product Dimensions 30" (76.2 cm) Cooktop - for standard and electric models Parts supplied ■ Vent grille ■ Pre-filter Parts needed ■ A UL listed or CSA approved strain relief for 2.2 cm) knockout. ■ A UL listed or CSA approved conduit connector for ¹⁄₂" (1.3 cm) trade-size metal-clad conduit ■ UL listed wire connectors ■ Metal ducting ■ Wall cap 6" (15.2 cm) Round Surface Wall Cap Damper Order Part Number A406 5" (12.7 cm) Round Surface Wall Cap Damper Order Part Number A405 3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper Order Part Number A403 To order, see the "Assistance or Service" section of the Use and Care Guide. ■ Vent clamps Check local codes. Check existing electrical supply. See "Electrical Requirements" section. It is recommended that all electrical connections be made by a licensed, qualified electrical installer. Location Requirements IMPORTANT: Observe all governing codes and ordinances. When installing cooktop, use minimum dimensions given. ■ To eliminate the risk of burns or fire by reaching over the heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets. ■ Use the countertop opening dimensions that are given with these Installation Instructions. Given dimensions are minimum clearances and provide 0" (0 cm) clearance. B C A A. Model/serial rating/clearance plate location B. 21" (53.4 cm) screw head to screw head C. 22" (52.3 cm) without stainless steel trim or 21 54.8 cm) with stainless steel trim A B C D E F H G I A. 30 76.3 cm) with stainless steel trim B. 29 76.1 cm) without stainless steel trim C. 14 36.4 cm) D. 3 10.1 cm) E. 18 46.8 cm) F. 1 3.4 cm) G. 13 33.3 cm) H. 14 36.0 cm) I. 28⁵⁄₈" (72.7 cm) screw head to screw head 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Parts supplied
Vent grille
Pre-filter
Parts needed
A UL listed or CSA approved strain relief for
⁷⁄₈
" (2.2 cm)
knockout.
A UL listed or CSA approved conduit connector for
¹⁄₂
" (1.3 cm) trade-size metal-clad conduit
UL listed wire connectors
Metal ducting
Wall cap
6" (15.2 cm) Round Surface Wall Cap Damper
Order Part Number A406
5" (12.7 cm) Round Surface Wall Cap Damper
Order Part Number A405
3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper
Order Part Number A403
To order, see the “Assistance or Service” section of the Use
and Care Guide.
Vent clamps
Check local codes. Check existing electrical supply. See
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Location Requirements
IMPORTANT:
Observe all governing codes and ordinances.
When installing cooktop, use minimum dimensions given.
To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.
Use the countertop opening dimensions that are given with
these Installation Instructions. Given dimensions are
minimum clearances and provide 0" (0 cm) clearance.
Grounded electrical supply is required. See “Electrical
Requirements” section.
If cabinet has drawers, drawers will need to be removed and
drawer fronts installed on front of cabinet.
IMPORTANT:
An under-counter built-in oven cannot be installed
under this product.
Product Dimensions
30" (76.2 cm) Cooktop - for standard and electric models
Tape measure
Flat-blade screwdriver
Phillips head screwdriver
Drill
Level
6" socket extension
Marker or pencil
Pliers
¼" drill bit
Jigsaw
Ratchet with
³⁄₈
"socket
A. Model/serial rating/clearance plate location
B. 21" (53.4 cm) screw head to screw head
C. 22" (52.3 cm) without stainless steel trim or
21
³⁷⁄₆₄
" (54.8 cm) with stainless steel trim
A. 30
¹⁄₃₂
" (76.3 cm) with stainless steel trim
B. 29
¹⁵⁄₁₆
" (76.1 cm) without stainless steel trim
C. 14
⁵⁄₁₆
" (36.4 cm)
D. 3
³¹⁄₃₂
" (10.1 cm)
E. 18
¹³⁄₃₂
" (46.8 cm)
F. 1
¹¹⁄₃₂
" (3.4 cm)
G. 13
³⁄₃₂
" (33.3 cm)
H. 14
³⁄₁₆
" (36.0 cm)
I. 28
⁵⁄₈
" (72.7 cm) screw head to screw head
A
B
C
A
C
I
G
E
D
B
F
H