Kodak ATS Operation Manual - Page 17
Reading Light, Standby Light, Special-Application Receptacle, Model E Plus only
UPC - 041771070632
View all Kodak ATS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Reading Light Operation To illuminate a small area for reading, lift the reading light cover while the projector lamp is on. Standby Light A glowing standby light indicates a (Model E Plus only) "ready" condition. In a dissolve program, it indicates that • both projectors are receiving power • both power switches are set at fan • both projection lamps are properly installed, not burned out, and ready • both standby lights are operational • all thermal fuses are functional Special-Application The special-application receptacle allows additional external control and Receptacle programming capability. It provides 22.5 V low-voltage power isolated from the main power line. Use this receptacle for: • automatic "return-to-zero" devices (models A and E Plus) • a low-voltage power supply • a dark shutter switch The receptacle accepts 8-pin plugs and DIN-type plugs with 3 or 5 pins at 180˚. (See "Appendix A" for contact identification descriptions.) KODAK EKTAGRAPHIC III Slide Projector 13