Konica Minolta magicolor 1650EN magicolor 1650EN Reference Guide - Page 220
Main Menu - System Default, Emulations - Postscript, Error Main Menu - Interface Menu
View all Konica Minolta magicolor 1650EN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 220 highlights
PostScript The Print - Default Setting - PostScript window provides the following parameters for configuration. The settings are arranged in 3 columns: Current, Custom, Factory. Item PS Error Page PS Protocol Ethernet Submit button Reset button Save Custom button Description Print an error page if the print job cannot be printed or creates an error. Choices: On, Off Default: On Configuration Menu Equivalent: MAIN MENU - SYSTEM DEFAULT EMULATIONS - POSTSCRIPT ERROR PAGE Specifies the binary communications protocol (BCP). Choices: Binary, Quoted Binary Default: Binary Configuration Menu Equivalent: MAIN MENU - INTERFACE MENU ETHERNET - PS PROTOCOL Saves and applies any changes made. Resets all configuration settings to previous values. Saves the Current values of the parameters as the Custom settings. Using the Restore Custom button, you can change the parameter settings back to the Custom settings after changes are made. Configuring the Printer (User Mode) 7-35