Kyocera KM-C4035E PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 252
Rwer D
View all Kyocera KM-C4035E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 252 highlights
PRESCRIBE Command Reference RWER D - [Read/Write External Resource] Delete data on external media Format RWER D, medium, data-type, 'partition-name'; Parameters medium: 0 = hard disk or RAM disk A = memory card data-type: type of data to be deleted 1 = Font data 2 = Printable data 16 = Macro data 112 = File data 128 = API data (downloadable program) partition-name: Name of partition from which data is deleted Function The RWER D command deletes data on any external media whether it is a memory card or the hard disk. This command has no effect if the media has been write protected using KPDL or PJL. The partition name may be a maximum of 15 printable ASCII characters (20H through 7EH); upper and lower case letters are regarded distinct. A partition name may not have leading spaces, and in the command, the partition name must be enclosed in single or double quotation marks. A partition list is not automatically printed when deleting data on external media, even though the automatic printing of partition information was enabled (by the RWER I command). ( See page 244.) A command error results and the command has no effect if parameters other than the above are used. This command causes a page break. 242