LG CDE3379WN Owner's Manual - Page 30

Test Mode

Page 30 highlights

Part 5 PROGRAMMING MODE - Test Mode Diagnostic tests : (display) This program has been added for testing the dryer and detecting errors. Entering the test mode Data Name Button Display Description Entering the test mode 1. Entering programming mode 2. WHITES AND COLORS 3. START Insert service card (card type), open the service door (coin type). Press the WHITES AND COLORS button. Then appears in the display. Enter the diagnostic test mode. 1 Pressing the START button cycles to the next test function. Number of times the START button is pressed None 1 time Checking point Check the version and code of machine. ■ ELECTRIC TYPE : US:OE ■ GAS TYPE : US:Og Display LqC 1 Version and code of machine (All LED on) Display US:OE or US:Og and EU:XX alternately. XX is the version number. 2 times 3 times 4 times 5 times 6 times During check, if the door is open. During check, if the door is closed Motor runs. ■ ELECTRIC TYPE: Heater runs. Motor + Heater 1 (2700W) ■ GAS TYPE: GAS valve runs. Motor + Valve ■ ELECTRIC TYPE: Heater runs. Motor + Heater 1 +Heater 2 (5400W) ■ GAS TYPE: GAS valve runs. Motor+Valve LED & KEY CHECK Press WHITES AND COLORS button. Press PERMANENT PRESS button. Press DELICATES button. Test ends. Door switch (Motor & Heater Off, Buzzer beeps seven times) Test goes back at step 2. (Motor on & Heater Off) Measured moisture value (70~239) Current temperature (5~70) (Displays the temperature inside the drum in ° Celsius.) Current temperature (5~70) (Displays the temperature inside the drum in ° Celsius.) Version and code of machine LqC1 dE (The door is open. Please close the door completely) Measured moisture value (70~239) Note During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically. Do not use . 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

30
Part 5
PROGRAMMING MODE -
Test Mode
Data Name
Entering
the test mode
1. Entering programming mode
2. WHITES AND COLORS
3. START
Insert service card (card type), open the service door (coin type).
Press the
WHITES AND COLORS button.
Then
appears in the display.
Enter the diagnostic test mode.
Button
Display
Description
Entering the test mode
Diagnostic tests :
(display)
This program has been added for testing the dryer and detecting errors.
1
Pressing the START button cycles to the next test function.
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
Note
Number of times the START
button is pressed
Display
Checking point
None
1 time
2 times
3 times
4 times
5 times
6 times
During check, if the door is open.
During check, if the door is closed
Check the version and code of machine.
ELECTRIC TYPE : US:OE
GAS TYPE : US:Og
Motor runs.
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2700W)
GAS TYPE: GAS valve runs.
Motor + Valve
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 +Heater 2 (5400W)
GAS TYPE: GAS valve runs.
Motor+Valve
LED & KEY CHECK
Press WHITES AND COLORS button.
Press PERMANENT PRESS button.
Press DELICATES button.
Test ends.
Door switch
(Motor & Heater Off, Buzzer beeps seven
times)
Test goes back at step 2.
(Motor on & Heater Off)
LqC 1
Version and code of machine (All LED on)
Display
US:OE or US:Og and EU:XX
alternately. XX is the version number.
Measured moisture value (70~239)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Current temperature (5~70)
(Displays the temperature inside the drum in
° Celsius.)
Version and code of machine
LqC1
dE
(The door is open. Please close the door
completely)
Measured moisture value (70~239)