LG DLG7188WM Service Manual - Page 15

Component Testing Information - reset

Page 15 highlights

5 COMPONENT TESTING INFORMATION ! CAUTION When checking the Component, be sure to turn the power off, and do voltage discharge sufficiently. Component 1. Thermal cut off • Check Top Marking: N130 2. Hi limit Thermostat (Auto reset) 3. Outlet Thermostat ( Auto reset) • Check Top Marking: N85 4. Lamp holder Test Procedure Check result Remark Measure resistance of terminal If thermal fuse is open must • Heater case- to terminal be replaced Safety Open at 266 ± 12°F (130 ± 7°C) Resistance value ∞ • Electric type Auto reset 31°F (35°C) Continuity (250°F ) < 1Ω Same shape as Outlet Thermostat. Measure resistance of terminal to terminal Open at 257 ± 9°F (125 ± 5°C) Close at 221 ± 9°F (105 ± 5°C) Resistance value ∞ Resistance value < 5Ω Measure resistance of terminal to terminal Open at 185 ± 9°F (85 ± 5°C) Close at 149 ± 9°F (65 ± 5°C) Same shape as Thermal cut off. Resistance value ∞ Resistance value < 5Ω Measure resistance of terminal Resistance value: to terminal 80Ω ~ 100Ω • Heater case Hi limit • Electric type • Blow housing Safety • Electric type 5. Door switch 6. Idler switch Measure resistance of the following terminal 1) Door switch knob: open Terminal: "COM" - "NC" (1-3) Terminal: "COM" - "NO" (1-2) 2) Door switch push: push Terminal: "COM" - "NC" (1-3) Terminal: "COM" - "NO" (1-2) Resistance value < 1Ω Resistance value ∞ Resistance value ∞ Resistance value < 1Ω The state that Knob is pressed is opposite to Open condition. Measure resistance of the following terminal: "COM - NC" 1. lever open Resistance value < 1Ω 2. Lever push (close) Resistance value ∞ 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

14
When checking the Component, be sure to turn the power off, and do voltage discharge
sufficiently.
COMPONENT TESTING INFORMATION
5
!
CAUTION
Component
Test Procedure
Check result
Remark
1. Thermal cut off
• Check Top Marking:
N130
Measure resistance of terminal
to terminal
±
Open at 266 ± 12°F
(130 ± 7°C)
²
Auto reset 31°F (35°C)
Same shape as Outlet Thermostat.
If thermal fuse is open must
be replaced
±
Resistance value
²
Continuity (250°F
) < 1Ω
• Heater case-
Safety
• Electric type
2. Hi limit Thermostat
(Auto reset)
Measure resistance of terminal
to terminal
±
Open at 257 ± 9°F
(125 ± 5°C)
²
Close at 221 ± 9°F
(105 ± 5°C)
±
Resistance value
²
Resistance value < 5Ω
• Heater case -
Hi limit
• Electric type
3. Outlet Thermostat
( Auto reset)
• Check Top Marking:
N85
Measure resistance of terminal
to terminal
±
Open at 185 ± 9°F
(85 ± 5°C)
²
Close at 149 ± 9°F
(65 ± 5°C)
Same shape as Thermal cut off.
±
Resistance value
²
Resistance value < 5Ω
• Blow housing -
Safety
• Electric type
4. Lamp holder
Measure resistance of terminal
to terminal
Resistance value:
80Ω ~ 100Ω
6. Idler switch
Measure resistance of the
following
terminal:
“COM - NC”
1. lever open
±
Resistance value < 1Ω
2. Lever push (close)
²
Resistance value
5. Door switch
Measure resistance of the
following
terminal
1) Door switch knob: open
±
Terminal: “COM” - “NC” (1-3)
²
Terminal: “COM” - “NO” (1-2)
2) Door switch push: push
±
Terminal: “COM” - “NC” (1-3)
²
Terminal: “COM” - “NO” (1-2)
±
Resistance value < 1Ω
²
Resistance value
±
Resistance value
²
Resistance value < 1Ω
The state that
Knob is
pressed is
opposite to
Open
condition.