LG KU250 Service Manual - Page 93
Power ON Troubleshooting
View all LG KU250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
4. TROUBLE SHOOTING 4.9 Power ON Troubleshooting Power On sequence of U250/KU250 is : PWR key press → PM_ON_SW_N go to low, PM6650 KPDPWR_N (pin24) → PM6650 Power Up → VREG_MSMC_1.2V, VREG_MSME_1.8V, VREG_MSMP_2.7V, VREG_MSMA_2.6V, VREG_TCXO_2.85V power up and system reset assert to MSM6245 → Phone booting and PS_HOLD assert to PMIC Start Battery voltage. higher than 3.20V? YES Key press? NO Change or charging the Battery NO Check the Key Dome YES VREG_MSMC_1.2V,VREG_MSMP_2.7V, VREG_MSME_1.8V, VREG_TCXO_2.85V, VREG_MSMA_2.6V power up? NO Change the Main board YES Is clock ok? R306 : 19.2M X300 : 32.768Khz YES Change the Main board NO Check the TXCO - 94 -
4.9 Power ON Troubleshooting
Power On sequence of U250/KU250 is :
PWR key press
→
PM_ON_SW_N go to low, PM6650 KPDPWR_N (pin24)
→
PM6650 Power Up
→
VREG_MSMC_1.2V, VREG_MSME_1.8V, VREG_MSMP_2.7V, VREG_MSMA_2.6V,
VREG_TCXO_2.85V power up and system reset assert to MSM6245
→
Phone booting and
PS_HOLD assert to PMIC
4. TROUBLE SHOOTING
- 94 -
Start
Battery voltage. higher
than 3.20V?
Key press?
VREG_MSMC_1.2V,VREG_MSMP_2.7V,
VREG_MSME_1.8V, VREG_TCXO_2.85V,
VREG_MSMA_2.6V power up?
Is clock ok?
R306 : 19.2M
X300 : 32.768Khz
Change the Main board
Change or charging the
Battery
Check the Key Dome
Change the Main board
Check the TXCO
NO
YES
YES
YES
YES
NO
NO
NO