LG LSC23924SW Owner's Manual - Page 13

Installation Instructions

Page 13 highlights

REFRIGERATOR INSTALLATION INSTALLATION INSTRUCTIONS Install the shutoff valve on the nearest frequently used drinking water line. 1. SHUT OFF THE MAIN WATER SUPPLY Turn on the nearest faucet to relieve the pressure on the line. 2. CHOOSE THE VALVE LOCATION Choose a location for the valve that is easily accessible. It is best to connect into the side of a vertical water pipe. When it is necessary to connect into a horizontal water pipe, make the connection to the top or side, rather than at the bottom, to avoid drawing off any sediment from the water pipe. 3. DRILL THE HOLE FOR THE VALVE Drill a ¼" (6.35 mm) hole in the water pipe using a sharp bit. Remove any burrs resulting from drilling the hole in the pipe. Take care not to allow water to drain into the drill. Failure to drill a ¼" (6.35 mm) hole may result in reduced ice production or smaller cubes. NOTE: Licensed plumbers must use only cooper tubing NDA tubing #49595 or 49499 or Cross Link Polyethylene (PEX) tubing. 4. FASTEN THE SHUTOFF VALVE Fasten the shutoff valve to the cold water pipe with the pipe clamp. Pipe Clamp 5. TIGHTEN THE PIPE CLAMP Tighten the clamp screws until the sealing washer begins to swell. NOTE: Do not overtighten or you may crush the tubing. Pipe Clamp Washer Inlet End Clamp Screw 6. ROUTE THE TUBING Route the tubing between the cold water line and the refrigerator. Route the tubing through a hole drilled in the wall or floor (behind the refrigerator or adjacent base cabinet) as close to the wall as possible. NOTE: Be sure there is sufficient extra tubing, [about 8 feet (2.4 m) coiled into 3 turns of about 10" (254 mm) diameter] to allow the refrigerator to move out from the wall after installation. 7. CONNECT THE TUBING TO THE VALVE Place the compression nut and ferrule (sleeve) for copper tubing onto the end of the tubing and connect it to the shutoff valve. Make sure the tubing is fully inserted into the valve. Tighten the compression nut securely. Saddle-Type Shutoff Valve Compression Nut Saddle-Type Shutoff Valve Vertical Cold Water Pipe NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber. Packing Nut Outlet Valve Ferrule (sleeve) NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

13
Drill a
¼ (6.35 mm)hole in the water
pipe using a sharp bit.
Remove any burrs
resulting from drilling the
hole in the pipe. Take care
not to allow water to drain
into the drill. Failure to drill
a
¼
(6.35 mm) hole may result in reduced ice
production or smaller cubes.
3. DRILL THE HOLE FOR THE VALVE
NOTE:
Licensed plumbers must use only cooper tubing
NDA tubing #49595 or 49499 or Cross Link
Polyethylene (PEX) tubing.
4. FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water pipe with
the pipe clamp.
NOTE:
Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle
valves are illegal and use is not permitted in
Massachusetts. Consult with your licensed
5. TIGHTEN THE PIPE CLAMP
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE:
Do not overtighten or you may crush the tubing.
6. ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
floor (behind the refrigerator or adjacent base cabinet) as
close to the wall as possible.
NOTE:
Be sure there is sufficient extra tubing, [about 8 feet
coiled into 3 turns of about 10” (254 mm)
(2.4 m)
diameter] to
to move out from
allow the refrigerator
the wall after installation.
Vertical Cold
Water Pipe
Saddle-Type
Shutoff Valve
Pipe Clamp
Washer
Inlet End
Pipe Clamp
Clamp Screw
7. CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and connect it
to the shutoff valve. Make sure the tubing is fully inserted
into the valve. Tighten the compression nut securely.
Saddle-Type
Shutoff Valve
Packing
Nut
Outlet
Valve
Ferrule (sleeve)
Compression
Nut
1. SHUT OFF THE MAIN WATER SUPPLY
Turn on the nearest faucet to relieve the pressure on
the line.
Choose a location for the valve that
is easily accessible. It is best to connect
into the side of a vertical water pipe.
When it is necessary to connect into a
horizontal water pipe, make the
connection
rather
to the top or side,
than at the bottom, to avoid drawing
off any sediment from the water pipe.
2. CHOOSE THE VALVE LOCATION
INSTALLATION INSTRUCTIONS
Install the shutoff valve on the nearest frequently used
drinking water line.
REFRIGERATOR INSTALLATION
plumber.
NOTE:
Commonwealth of Massachusetts Plumbing Codes
248CMR shall be adhered to. Saddle
valves are
Massachusetts.
illegal and use is not permitted in
Consult
plumber.
with your licensed