LG LSC27914SB Owner's Manual - Page 57
Charge of temperature - Impact.
View all LG LSC27914SB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
CLAIMS. 3. Refrigeration is weak. CAUSES AND CHECK POINTS. 4) No cooling air circulation. Faulty fan motor. Fan is constrained. Fan shroud contact. - Clearance. Damping evaporator contact. Accumulated residual frost. Small cooling air discharge. Insufficient motor RPM Fan overload. - Fan misuse. Bad low termperature RPM characteristics. Rated power misuse. Low voltage. Faulty fan. Fan misuse. Bad shape. Loose connection. - Not tightly connected. Insert depth. Shorud. Bent. Ice and foreign materials on rotating parts. HOW TO CHECK 5) Compressor capacity. Rating misuse. Small capacity. Low valtage. 6) Refrigerant too much or too little. Malfunction of charging cylinder. Wrong setting of refrigerant. Insufficient compressor. - Faulty compressor. 7) Continuous operation - No contact of temperature controller. - Foreign materials. • Check visually after disassembly. 8) Damper opens continuously. Foreign materials Adiabatics liquid dump. • Check visually after jammed. The EPS (styrofoam) drip tray has sediment in it. disassembly. A screw or other foreign material has fallen into the drip tray or damper. Failed sensor. - Position of sensor. Characteristics of damper. Bad characteristics of its own temperatue. Parts misuse. Charge of temperature - Impact. characteristics. 9) Food storing place. - Near the outlet of cooling air. - 56 -