LG RCS10MPA Service Manual - Page 22

D. Pcb Assembly Removal, E. Door Main Assembly Removal

Page 22 highlights

D. PCB ASSEMBLY REMOVAL 1) Remove the control panel assembly from the cavity. (Refer to control panel assembly removal on previous page.) 2) Remove screws which hold the PCB SUB ASSÕY to the control panel. 3) Disconnect the flat cable from the PCB SUB ASSÕY and take off the PCB SUB ASSÕY Control PanPelCB SPuCbBASsumb Asm Control Panel Key Membrane RReemmoovvee cchhookkee ccoovveerr Button Spring Door Open Button Release Lever E. DOOR MAIN ASSEMBLY REMOVAL 1) Open the door. 2) Remove the choke cover cap very carefully with a flat-blade screwdriver. CAUTION: Be careful not to damage door seal plate by screwdriver. 3) Lift up and push the door. NOTE: 1. After replacing the door, be sure to check that the primary switch, monitor switch, and secondary switch operate normally. 2. After replacing the door, check for microwave energy leakage with a survey meter. Microwave energy must be below the limit of 4 mW/cm2. (with a 275 ml water load) 3. When mounting the door assembly to the oven assembly, be sure to adjust the door assembly parallel to the chassis. Also adjust so the door has no play between the inner door surface and oven frame assembly. If the door assembly is not mounted properly, microwaves may leak from the clearance between the door and the oven. 5-4 RReemmoovvee ddoooorr DDoorosr esaelapl lpaltaete SSppaacceerr

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

D. PCB ASSEMBLY REMOVAL
1) Remove the control panel assembly from the
cavity. (Refer to control panel assembly removal
on previous page.)
2) Remove screws which hold the PCB SUB ASS²Y to
the control panel.
3) Disconnect the flat cable from the PCB SUB
ASS²Y and take off the PCB SUB ASS²Y
E. DOOR MAIN ASSEMBLY REMOVAL
1) Open the door.
2) Remove the choke cover cap very carefully with a flat-blade
screwdriver.
CAUTION: Be careful not to damage door seal plate
by screwdriver.
3) Lift up and push the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 4 mW/cm
2
. (with a 275 ml water
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
5-4
Door seal plate
Control Panel
Button Spring
Door Open Button
Key Membrane
PCB Sub Asm
Release Lever
Remove door
Remove choke cover
Spacer