Lacie Spare 12big Rack Network User Manual - Page 16
Enclosure Management
View all Lacie Spare 12big Rack Network manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
LaCie 12big Rack Network User Manual 1.9.4. Blanking Plates Blanking Plates must be fitted in any vacant PSU bay or PCI card slots at the rear of the enclosure to maintain airflow and ensure correct operation. CAUTION: Operation of the Enclosure with ANY modules missing will disrupt the airflow and the drives will not receive sufficient cooling. 1.10. Enclosure Management The Enclosure Management PCB provides the required reporting functionality. No Operating System should be required to manage the following functions: ✦✦ Audible Alarm Control ✦✦ PSU Status monitoring ✦✦ Fan Speed reporting ✦✦ Fan Speed control ✦✦ Fan Fail monitoring (with Fault LED) ✦✦ Enclosure Temperature monitoring for CPU(s), FBDIMM(s), Motherboard, plenum ✦✦ Alarm on over temperature ✦✦ 3.5" HDD presence detection ✦✦ 3.5" HDD Fault LED control ✦✦ Front panel LED's and switches (including Enclosure Fault In- dication) ✦✦ Intrusion detection ✦✦ Serial EEPROM to store system setup parameters -- Serial number, machine type, number of drive bays etc. StorView® management suite uses the industry standard SES communications protocol, which is the only supported communication method to the enclosure firmware. Other tools may cause unpredictable side effects and hence are not supported. SES support is at ANSI SES 2.0 level and supports SES Pages 0, 1, 2, 5, 7, Ah and Eh. Download of the Enclosure firmware is supported via SES Page Eh. During firmware download all RAID data activity must be stopped. System Overview page 16