Lantronix MSSLite MSS Reference Manual - Page 62

Crypt Password

Page 62 highlights

Crypt Password 2.69 Crypt Password Command Reference CRYPT PASSWORD password Changes the password used for the encryption mode environment string (:Y). Both ends of the connection must agree on the encryption password being used. You must reboot after changing the encryption password. This command can be used to configure an MSS to MSS encrypted session. Set the encryption password on both units to be the same password, reboot both units, then telnet either to one of the unit's local prompts (i.e. socket 2100) or serial port (i.e. socket 210x where x is the serial port number) using the :Y environment string. Sockets 2100 and 210x are assumed to be encrypted on the receiving MSS. Restrictions Requires privileged user status. Parameters password Enter a new encryption password. The password can be up to 7 alphanumeric or escaped hex (\xx) characters and is case sensitive. See Also Change Dedicated, page 2-19; Hostlist, page 2-58. 2-52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93

Crypt Password
Command Reference
2-
52
2.69
Crypt Password
Changes the password used for the encryption mode environment string (:Y). Both ends of the connection
must agree on the encryption password being used. You must reboot after changing the encryption
password.
This command can be used to configure an MSS to MSS encrypted session. Set the encryption password on
both units to be the same password, reboot both units, then telnet either to one of the unit’s local prompts
(i.e. socket 2100) or serial port (i.e. socket 210x where x is the serial port number) using the :Y environment
string. Sockets 2100 and 210x are assumed to be encrypted on the receiving MSS.
Restrictions
Requires privileged user status.
Parameters
password
Enter a new encryption password. The password can be up to 7 alphanumeric
or escaped hex (\xx) characters and is case sensitive.
See Also
Change Dedicated, page 2-19; Hostlist, page 2-58.
CRYPT PASSWORD