Lantronix TN-QSFP-100G-xxxxx User Guide Optical Specifications The Optical Spec for all Lantronix SFPs are listed at www.transition.com/sfp.pdf. Applications: Fiber Connections with SFPs SFP applications include 100G Data Center connectivity, 100G Aggregation and Backplane applications, 100Gbase-X Ethernet, etc. The TN-QSFP-100G-CWDM4 can be used in a 100G CWDM4 application with FEC. SFP Unpacking Before you start installing the TN-QSFP-100G-xxxxx, verify that the package contains these items: o One TN-QSFP-100G-xxxxx o One Documentation Postcard Please notify your sales representative immediately if any of the above items is missing or damaged. Save the packaging for possible future use. SFP Installation Cautions • The SFP tranceiver module is keyed to only be installed one way. However, if forced the wrong way, damage may occur. • Avoid getting dust or other contaminants into the fiber bore of the SFP transceiver module, as this will cause the optics to not operate properly. • Clean the optic surfaces of the optical fiber before you plug them back in to the optical bores of another SFP tranceiver module. • Each port must match the wavelength specifications on the other end of the cable, and the cable must not exceed the specified cable length for reliable communications. Installing the TN-QSFP-100G-xxxxx The TN-QSFP-100G-xxxxx is used primarily in short reach applications in switches, routers, and data center equipment where it provides higher density than SFP+ modules. Note: The multiple-fiber push-on (MPO) connectors and the duplex LC connectors on the TN-QSFP100G-xxxxx support network interface cables with either Physical contact (PC) or Ultra-Physical Contact (UPC) flat-polished face types. The MPO connectors and the duplex LC connectors on the TN-QSFP100G-xxxxx do not support network interface cables with an angle-polished contact (APC) face type. Warning: Invisible laser radiation may be emitted from the aperture of the port when no cable is connected; avoid exposure to laser radiation and do not stare into open apertures. Warning: Ultimate disposal of this product must be handled according to all national laws and regulations. Warning: Use of controls, adjustments, or performing procedures other than those specified may result in hazardous radiation exposure. 33765 Rev. C http://www.lantronix.com/ Page 6 of 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Lantronix
TN-QSFP-100G-xxxxx User Guide
33765 Rev. C
Page 6 of 15
Optical Specifications
The Optical Spec for all Lantronix SFPs are listed at
www.transition.com/sfp.pdf
.
Applications: Fiber Connections with SFPs
SFP applications include 100G Data Center connectivity, 100G Aggregation and Backplane applications,
100Gbase-X Ethernet, etc. The TN-QSFP-100G-CWDM4 can be used in a 100G CWDM4 application
with FEC.
SFP Unpacking
Before you start installing the TN-QSFP-100G-xxxxx, verify that the package contains these items:
o
One TN-QSFP-100G-xxxxx
o
One Documentation Postcard
Please notify your sales representative immediately if any of the above items is missing or damaged.
Save the packaging for possible future use.
SFP Installation
Cautions
The SFP tranceiver module is keyed to only be installed one way. However, if forced the wrong way,
damage may occur.
Avoid getting dust or other contaminants into the fiber bore of the SFP transceiver module, as this will
cause the optics to not operate properly.
Clean the optic surfaces of the optical fiber before you plug them back in to the optical bores of
another SFP tranceiver module.
Each port must match the wavelength specifications on the other end of the cable, and the cable
must not exceed the specified cable length for reliable communications.
Installing the TN-QSFP-100G-xxxxx
The TN-QSFP-100G-xxxxx is used primarily in short reach applications in switches, routers, and data
center equipment where it provides higher density than SFP+ modules.
Note
: The multiple-fiber push-on (MPO) connectors and the duplex LC connectors on the TN-QSFP-
100G-xxxxx support network interface cables with either Physical contact (PC) or Ultra-Physical Contact
(UPC) flat-polished face types. The MPO connectors and the duplex LC connectors on the TN-QSFP-
100G-xxxxx do not support network interface cables with an angle-polished contact (APC) face type.
Warning
: Invisible laser radiation may be emitted from the aperture of the port when no cable is
connected; avoid exposure to laser radiation and do not stare into open apertures.
Warning
: Ultimate disposal of this product must be handled according to all national laws and
regulations.
Warning
: Use of controls, adjustments, or performing procedures other than those specified may result in
hazardous radiation exposure.