Page 33 highlights
Diagnostic Error Code 175-199-XXXThermal Sensor(s) test failed, cause unknown 175-250-XXX 175-251-XXXThermal Sensor(s) limit error 185-000-XXXAsset Security Test Passed 185-XXX-XXXAsset Security failure 185-278-XXXAsset Security Chassis Intrusion 201-000-XXXSystem Memory Test Passed 201-XXX-XXXSystem Memory error 202-000-XXXSystem Cache Test Passed 202-XXX-XXXSystem Cache error 206-000-XXXDiskette Drive Test Passed 206-XXX-XXXDiskette Drive error 215-000-XXXCD-ROM Drive Test Passed 215-XXX-XXXCD-ROM Drive error 217-000-XXXHard Disk Drive Test Passed FRU/Action 1. Go to the ″Undetermined problems″ section 2. Flash the system and re-test 3. Replace component under function test 1. Check fans 2. Check Power supply 3. Microprocessor 4. System board 1. No action 1. Flash system 2. System board 1. Assure Asset Security Enabled 2. C2 Cover Switch 3. System board 1. No action 1. Replace the memory module called out by the test 2. System board 1. No action 1. Cache, if removable 2. System board 3. Microprocessor 1. No action 1. Diskette Drive Cable 2. Check power supply voltages 3. Diskette drive 4. System board 1. No action 1. CD-ROM Drive Cable 2. Check power supply voltages 3. CD-ROM drive 4. System board 1. No action Chapter 1. IBM PC Enhanced Diagnostics error codes 19