Lenovo ThinkPad Edge E50 Hardware Maintenance Manual - Page 49

Symptom-to-FRU index, Numeric error codes, Shut down, Hibernate

Page 49 highlights

2. Click the triangle mark on the right side of the Shut down icon; then select Hibernate. To return from hibernation mode, press the power button for more than 4 seconds. Symptom-to-FRU index This section contains following information: • "Numeric error codes" on page 43 • "Error messages" on page 45 • "No-beep symptoms" on page 46 • "LCD-related symptoms" on page 46 • "Intermittent problems" on page 46 • "Undetermined problems" on page 47 The symptom-to-FRU index in this section lists symptoms and errors and their possible causes. The most likely cause is listed first, in boldface type. Note: Do the FRU replacement or other actions in the sequence shown in the column headed "FRU or action, in sequence." If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU. This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next. A numeric error is displayed for each error detected in POST or system operation. In the displays, n can be any number. If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not described there, go to "Intermittent problems" on page 46. Note: For a device not supported by diagnostic codes in the ThinkPad Notebooks, see the manual for that device. Numeric error codes Table 2. Numeric error codes Symptom or error (beeps, if any) FRU or action, in sequence 0187 System board. EAIA data access error-The access to EEPROM is failed. (two short beeps) 0189 Invalid RFID configuration information area-The EEPROM checksum is not correct. (two short beeps) System board. 0190 Critical low-battery error (two short beeps) 1. Charge the battery pack. 2. Battery pack. 0191 System Security-Invalid Remote Change requested. 1. Run BIOS Setup Utility, and then save current setting by pressing F10. 2. System board. 0210 Stuck Key (two short beeps) Change keyboard, and restart the computer. Chapter 4. Related service information 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

2. Click the triangle mark on the right side of the
Shut down
icon; then select
Hibernate
.
To return from hibernation mode, press the power button for more than 4 seconds.
Symptom-to-FRU index
This section contains following information:
“Numeric error codes” on page 43
“Error messages” on page 45
“No-beep symptoms” on page 46
“LCD-related symptoms” on page 46
“Intermittent problems” on page 46
“Undetermined problems” on page 47
The symptom-to-FRU index in this section lists symptoms and errors and their possible causes. The most
likely cause is listed first, in boldface type.
Note:
Do the FRU replacement or other actions in the sequence shown in the column headed “FRU or
action, in sequence.” If replacing a FRU does not solve the problem, put the original part back in the
computer. Do not replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are likely to need to be
replaced next.
A numeric error is displayed for each error detected in POST or system operation. In the displays,
n
can
be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not
described there, go to “Intermittent problems” on page 46.
Note:
For a device not supported by diagnostic codes in the ThinkPad Notebooks, see the manual for
that device.
Numeric error codes
Table 2. Numeric error codes
Symptom or error (beeps, if any)
FRU or action, in sequence
0187
EAIA data access error—The access to EEPROM is failed.
(two short beeps)
System board.
0189
Invalid RFID configuration information area—The
EEPROM checksum is not correct.
(two short beeps)
System board.
0190
Critical low-battery error
(two short beeps)
1.
Charge the battery pack.
2. Battery pack.
0191
System Security—Invalid Remote Change requested.
1.
Run BIOS Setup Utility, and then save current
setting by pressing F10.
2. System board.
0210
Stuck Key
(two short beeps)
Change keyboard, and restart the computer.