LevelOne IES-1070 Manual - Page 5

Quick Start Guide

Page 5 highlights

Quick Start Guide This quick start guide describes how to install and use the Industrial Managed Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description The Port Status LEDs and Power Inputs Power Inputs + 12 48VDC PW1 Power Ground + 12 48VDC PW2 Power Ground Terminal Block Earth Ground Relay Output 1A @ 24VDC Relay Alarm warning signal disable for following: 1. The relay contact closes if Power1 and Power2 are both failed but Power3 on 2. The relay contact closes if Power3 is failed but Power1 and Power2 are both on  There are three power inputs can be used. Redundant power function is supported PW3 is DC Jack type with 12VDC input IES-1070 User Manual Page 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

IES-1070 User Manual
Page 5
Quick Start Guide
This quick start guide describes how to install and use the Industrial Managed Ethernet
Switch. This is the switch of choice for harsh environments constrained by space.
Physical Description
The Port Status LEDs and Power Inputs
Power Inputs
Terminal Block
PW1
+
12
48VDC
Power Ground
PW2
+
12
48VDC
Power Ground
Earth Ground
Relay Output
1A @ 24VDC
Relay Alarm warning signal disable for following:
1.
The relay contact closes if Power1 and Power2 are both failed but Power3 on
2.
The relay contact closes if Power3 is failed but Power1 and Power2 are both on
There are three power inputs can be used. Redundant power function is supported
PW3
is DC Jack type with 12VDC input