Lexmark E360DN Service Manual - Page 46
A recoverable MVRAM Cyclic Redundancy Check error, Replace the LVPS/HVPS. See
UPC - 734646084475
View all Lexmark E360DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
4513-420, -430 Error Description Action 936.01 No lock detected at normal motor start 936.02 No lock detected at motor start for motor ID 936.03 No halls detected at motor start 936.04 Failed to stop within timeout 936.05 Stall detected during speed control 937.00 Main transport motor lost lock 937.01 Main transport motor lost lock, detected by engine control 937.02 Overspeed detected during position control 937.03 Overspeed detected during speed control Power supply service errors 940.00 LVPS service error 940.01 Line frequency outside allowed range of 45Hz-64Hz 940.02 Line frequency below 43Hz 940.03 No zero cross detected on belt fuser model Replace the main motor gear drive. See "Main motor service check" on page 2-26 Replace the main motor gear drive. See "Main motor service check" on page 2-26 Replace the LVPS/HVPS. See "LVPS/HVPS service check" on page 2-25. Controller board and operator panel service errors 948.xx 949.xx Failed engine board Replace the controller board. See "Controller board service check" on page 2-22. 950.xx Mismatch between EEPROM and mirror memory Note: A new controller board or operator panel has been installed, and has not been properly prepared for this use. Install a new note. Do not install both the controller board and the operator panel at the same time without a POR in between. Install a new controller bored or operator panel. See "Controller board service check" on page 2-22 or "Operator panel service check" on page 2-27. 951.xx Error with secure NVRAM on the controller board Replace the controller board. See "Controller board service check" on page 2-22. 952.xx A recoverable MVRAM Cyclic Redundancy Check error Performing POR will clear this error. occurred. 953.xx NVRAM chip failure with mirror Replace the operator panel. See "Operator panel service check" on page 2-27. 954.xx 955.xx NVRAM chip failure with system part. The code ROM or NAND flash failed the Cyclic Redundancy Check or the NAND experienced an uncorrectible multi-bit failure. Replace the controller board. See "Controller board service check" on page 2-22. 956.00 RIP card failure: processor failure 956.01 Processor overtemp 957.xx RIP card failure: ASIC failure 958.xx Printer has performed more than 100 "shift and reflash" operations as a result of ECC bit corrections 2-18 Lexmark™ E360d, E360dn