Lexmark MX321 Forms and Bar Code Card P4.2 Technical Reference - Page 77
space width #1, value is 2.25
View all Lexmark MX321 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
PostScript emulation Key /Bars Type [int int] Lexmark Confidential until announced Range [12 27]-[24 72] dec Default value 12 dec (00 0C hex) /Spaces [int int] [12 27]-[24 72] dec 12 dec (00 0C hex) /EmbedText name /NoText /Under /Above /NoText 77 Description Optional. Sets the bar widths in /Units. Notes: • The bar width #2 value is 2.50 multiplied by the bar width #1 value. • Values beyond the defined range are clipped and set to the minimum and maximum values. Optional. Sets the space widths in /Units. Notes: • The minimum space width #2 value is 2.25 multiplied by the space width #1 value. The maximum value is 3 multiplied by the space width #1 value. • Values beyond the defined range are clipped and set to the minimum and maximum values. Optional. If available, this key determines the HRT location printed with the bar code.