Lexmark T630n Service Manual - Page 139
Output Bin Tests, Output Bin Test-Standard Bin
UPC - 734646532211
View all Lexmark T630n manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
4060-xxx Output Bin Tests Output Bin Test-Standard Bin This test is used to verify if the standard bin sensor is working correctly. To run the Standard Bin Sensor Test: 1. Select Output Bin Tests from the Diagnostic menu. 2. Select Output Bin Tests - Sensor Tests. 3. Select Sensor Tests - Standard Bin. "Standard Bin/Full=CL" message displays. Manually actuate the bin sensor by moving the flag in and out of the sensor. The display indicates OP (open) when the flag is out of the sensor and CL (closed) when the flag is in the sensor. 4. Press Return/Stop to exit the test. Output Bin Feed Test Note: If the Configure Bins printer setting is link rather than mailbox, the printer selects its own internal bin linking regardless of which output bin is selected for the feed test This test is used to verify that media can be fed to a specific output bin. No information is printed on the media fed to the output bin because the printhead is not turned on during this test. This test can be run from any input source and will support any size paper or envelope supported by the printer. To run the Output Bin Feed Test: 1. Select Feed Test from the Output Bin Test menu. 2. Select the output bin you want the paper to exit into. The standard bin as well as any output option bin installed on the printer is shown on the menu. (The output bin displayed is in the order installed on the printer.) 3. Select either Single (one sheet of media feeds to the selected output bin) or Continuous (media continues feeding to the selected output bin) until Return/Stop is pressed. 4. Press Return/Stop to exit the test. Diagnostic aids 3-11