LiftMaster LA400 LA400 Manual - Page 30
Adjustment
UPC - 753182403953
View all LiftMaster LA400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
ADJUSTMENT » SET DIP SWITCH SET DIP SWITCH The Save switch must be in the OFF position prior to adjusting the switches. After the adjustments are made the Save switch must be in the ON position in order for the changes to be saved. 1 Set the Save switch to the OFF position. 1 2 Set switch to Single for single gate installation. For Dual (Gate 1 and 2) installation set switch on Dual Mode. 3 Set the Save switch to the ON position. 2 OFF OFF SINGLE NO NO OFF OFF SINGLE NO NO 3 OFF OFF SINGLE NO NO O1 2 3 4 5 N O1 2 3 4 5 N O1 2 3 4 5 N O1 2 3 4 5 N OFF OFF SINGLE NO NO ON SAVE ON MAGLOCK DUAL MODE NC EDGE NC PHOTO S1 O1 2 3 4 5 N OFF OFF SINGLE NO NO ON SAVE ON MAGLOCK DUAL MODE NC EDGE NC PHOTO S1 ON ON DUAL MODE NC NC ON ON DUAL MODE NC NC ON SAVE ON DUAL MODE NC NC GATE 1 GATE 1 AND GATE 2 29