LiftMaster SL3000UL SL3000UL Manual - Page 15

Control Board Description, Omni Option Board Connection - dc

Page 15 highlights

C O N T R O L B O A R D D E SC R I P T I O N Plug-In Loop Detectors CENTER SAFETY EXIT 1 HP Board 1 Maglock/Solenoid Relay Module Connection Not Used Surge Suppressor Master/Second Connection W4 Jumper Wire W4 GBA MS LINK 22 Plug-In Loop Wires 21 ALARM SENSOR 2 SENSOR ALARM 3 DC-BACKUP SYSTEM ON SENSORS 20 TIMER 18 19 OFF 60 3 7 1 3 ON REVERSE SENSOR 1 17 COMMAND PROCESSED 3 1 15 FIRE DEPT. 16 EXIT LOOP 3 8 OPEN LEFT OPEN RIGHT 13 11 9 STRIKE OPEN RADIO RECEIVER GATE LOCKED 14 SAFETY LOOP 12 CENTER LOOP 10 RESET MOTOR CLOSE STOP OPEN 4 POWER OVERLOAD 5 MADE IN USA 6 UL Alarm Connection Safety Sensors Connection CENTER SAFETY EXIT Omni Option Board Connection 1 1HP Connection - Factory installed SL3000UL1HP™ Models. 12 Center Loop LED - Center loop detector activated when ON. 2 J3 Motor, Limit Switch, Maglock/Solenoid Connection 13 Strike Open LED - Strike connected device activated when ON. 3 DC2000™ Back-Up Power or Reset Switch/Interlock Connection 14 Safety Loop LED - Safety loop detector activated when ON. 4 Circuit Board Power LED - Operator power OK when ON. 15 Fire Dept LED - Key Switch activated when ON. 5 Overload LED - Operator power has overloaded when ON. 16 Exit Loop LED - Exit loop detector activated when ON. 6 On-Board 3 Button Station - Close, Stop, Open commands. 17 Command Processed LED - Successful command executed. 7 Timer - Timed close, see page 29. 18 Alarm Sensor - Limited Adjustment, page 30. 8 Gate Opening Direction Selector - Open Left, Open Right. 19 Reverse Sensor - Gate hit obstruction when ON. See page 30. 9 Gate Locked LED - Maglock/Solenoid is activated when on. 20 System On LED - Operator is successfully performing a command. 10 Reset Motor LED - Cycle operator power when ON. 21 J1 Surge Suppressor Data Connection 11 Radio Receiver LED- Radio transmitter is activated when ON. 22 M/S Link LED - Data being transferred between master and second operators when ON. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

13
CONTROL BOARD DESCRIPTION
CENTER
SAFETY
EXIT
CENTER SAFETY
EXIT
1
3
TIMER
SYSTEM ON
ALARM
SENSOR
OPEN
STOP
CLOSE
60
POWER
OVERLOAD
OFF
W4
OPEN LEFT
DC-BACKUP
ALARM
SENSOR
OPEN RIGHT
3
SENSORS
1
3
1
3
ON
G
B
MS LINK
A
MADE IN USA
FIRE
DEPT.
STRIKE
OPEN
RADIO
RECEIVER
EXIT
LOOP
REVERSE
SENSOR
SAFETY
LOOP
CENTER
LOOP
GATE
LOCKED
RESET
MOTOR
COMMAND
PROCESSED
1
4
3
1
2
5
2
3
6
4
5
7
6
8
7
8
9
9
10
10
11
11
12
13
15
14
16
17
20
19
18
21
22
12
13
14
15
16
17
18
19
20
21
22
1HP Connection -
Factory installed SL3000UL1HP™ Models.
J3 Motor, Limit Switch, Maglock/Solenoid Connection
DC2000™ Back-Up Power or Reset Switch/Interlock Connection
Circuit Board Power LED -
Operator power OK when ON.
Overload LED -
Operator power has overloaded when ON.
On-Board 3 Button Station -
Close, Stop, Open commands.
Timer -
Timed close, see page 29.
Gate Opening Direction Selector -
Open Left, Open Right.
Gate Locked LED -
Maglock/Solenoid is activated when on.
Reset Motor LED -
Cycle operator power when ON.
Radio Receiver LED-
Radio transmitter is activated when ON.
Center Loop LED -
Center loop detector activated when ON.
Strike Open LED -
Strike connected device activated when ON.
Safety Loop LED -
Safety loop detector activated when ON.
Fire Dept LED -
Key Switch activated when ON.
Exit Loop LED -
Exit loop detector activated when ON.
Command Processed LED -
Successful command executed.
Alarm Sensor -
Limited Adjustment, page 30.
Reverse Sensor -
Gate hit obstruction when ON. See page 30.
System On LED -
Operator is successfully performing a command.
J1 Surge Suppressor Data Connection
M/S Link LED -
Data being transferred between master and
second operators when ON.
Maglock/Solenoid
Relay Module Connection
Plug-In Loop Wires
Surge Suppressor
Master/Second Connection
W4 Jumper Wire
UL Alarm Connection
Safety Sensors
Connection
1 HP
Board
Omni Option Board Connection
Plug-In Loop Detectors
Not Used