LiftMaster SL3000UL SL3000UL Manual - Page 29

MHz 24Vdc Radio Receiver Programming - remotes

Page 29 highlights

WARNING 315 MHZ 24Vdc RADIO RECEIVER PROGRAMMING Setting Security Mode (High)­or (Normal): The receiver is factory set at HIGH security mode. To verify, refer to the label next to jumper P4. (See illustration below) The Receiver can be used with up to 15 rolling code remotes or pins in HIGH security mode. Alternately, it can be used with up to 31 of any type remote in NORMAL security mode, including any combination of rolling code, billion code, or dip switch remotes. When changing from NORMAL to HIGH security mode, all previous remote control codes must be erased. See next page to erase and reprogram remote controls that are being used. WWAARRNNIINNGG To prevent possible serious injury or death from a moving gate or garage door: • A LWAYS keep remote controls out of reach of children. NEVER permit children to operate, or play with remote control transmitters. WWAARRNNIINNGG • Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel. • ALWAYS keep gate or garage door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door. CWAAURTNIOING To AVOID damaging receiver, disconnect receiver's power before changing jumpers. ENGLISH CDeAfauUlt PTosiItioOn N P4 P2 ENGLISH HIGNHORAM DVEHIRGNHOTREMNCIA Changing security from High to Normal. Default Position AAWDDVAVERERRNTTINEENGNCCIIAA M C M C Changing output duration from Momentary to Constant. Setting Output Duration (M) or (C): AAWDDVAVERERNRTITNEENGNCCIIAA The receiver is factory set at (M) Momentary. To verify, refer to the label next to jumper P2. (See illustration above) For commercial applications, the receiver can be set to either (C) constant or (M) momentary closure. To reduce the risk of SERIOUS INJURY or DEATH, the use of CONSTANT OPERATION on residential operators is PROHIBITED. With the jumper in the (M) momentary position, the contacts will close for 1/4 second regardless of the length of remote control transmission. PAWRDEAVCREANRUITNCEIGNÓCNIA With the jumper in (C) constant position, the contacts will stay closed as long as the remote control continues transmitting. Push and HOLD remote button to open or close gate. 27 SPANISH PCRAEUCTAIUOCNIÓN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

27
HIGH
NORM
HIGH
NORM
M
C
M
C
Setting Security Mode (High) or (Normal):
Setting Output Duration (M) or (C):
P2
Changing security from High to Normal.
Default Position
Default Position
Changing output duration from Momentary to Constant.
The receiver is factory set at
HIGH
security mode. To verify, refer
to the label next to jumper P4. (See illustration below)
The Receiver can be used with up to
15
rolling code remotes or
pins in
HIGH
security mode.
Alternately, it can be used with up to
31
of any type remote in
NORMAL
security mode,
including any
combination of rolling code, billion code, or dip switch remotes.
When changing from
NORMAL
to
HIGH
security mode,
all previous
remote control codes must be erased.
See next page to erase and
reprogram remote controls that are being used.
The receiver is factory set at (
M
) Momentary. To verify, refer to
the label next to jumper P2. (See illustration above)
For commercial applications, the receiver can be set to either (
C
)
constant or (
M
) momentary closure.
With the jumper in the (
M
) momentary position, the
contacts will
close for 1/4 second regardless of the length of remote control
transmission.
With the jumper in (
C
) constant position, the
contacts will stay
closed as long as the remote control continues transmitting.
Push and
HOLD
remote button to open or close gate.
315 MHZ 24Vdc RADIO RECEIVER PROGRAMMING
To prevent possible SERIOUS INJURY or DEATH from a
moving gate or garage door:
• ALWAYS keep remote controls out of reach of children.
NEVER permit children to operate, or play with remote control
transmitters.
• Activate gate or door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to door travel.
• ALWAYS keep gate or garage door in sight until completely closed.
NEVER permit anyone to cross path of moving gate or door.
To AVOID damaging receiver, disconnect receiver’s power
BEFORE changing jumpers.
To reduce the risk of SERIOUS INJURY or DEATH, the use
of CONSTANT OPERATION on residential operators
is PROHIBITED.
CAUTION
WARNING
WARNING
P4
P2
P4