w i r i n g d i a GR a m • S L 3 0 0 0 u l 1 H P ™ Electronic Power Strip OFF ON Black White Chassis Ground White Wires Black Wires OmniControl™ Board J9 1 HP Board 1 Green 3 Black 5 White Motor CENTER SAFETY EXIT Not Used Input Power 120Vac, 60 Hz, Grounded Black 120Vac White Neutral Green Ground Black 120Vac White Neutral Green Ground J11 J12 J13 J10 W4 1 2 3 J2 GBA MS LINK J8 CENTER SAFETY EXIT 1 2 3 4 5 J1 6 ALARM SENSOR 6 5 4 3 2 1 J1 J3 2 43 6 6 Green 4 2 J7 SENSOR ALARM 1234567 J5 DC-BACKUP 3 J6 4 SYSTEM ON SENSORS 1 3 1 3 REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA Left Motor Relay Adapter Module (Optional) UL Alarm Limit Box Assy Right Factory Heater Note: Wires into main power and draws 3 amps. to J10 OmniControl™ Board Surge Suppressor Master/Second Connection to J2 OmniControl™ Board Note: See table on next page. Omni Option Board (Optional) 39 Reset Switch Interlock Assembly 12 3 1 2 3 4 5 6 1 2 3 4 5 6 7 ® OmniControl Surge Suppressor P/N Q410 Patent Pending J1 J3 J2 Green GBA M/S Link Chassis Ground Center Loop Safety Loop - Exit Fire Dept Strike Open Loop Key Switch Push Button + Radio Receiver Class 2 Supply 24 Volts DC Green/ Black Radio Receiver 315 MHz 24Vdc 4321 Green White Black Red Radio Harness

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

39
wiring diagram • SL3000uL1HP™
CENTER
SAFETY
EXIT
CENTER SAFETY
EXIT
1
3
TIMER
SYSTEM ON
ALARM
SENSOR
OPEN
STOP
CLOSE
60
POWER
OVERLOAD
OFF
W4
OPEN LEFT
DC-BACKUP
ALARM
SENSOR
OPEN RIGHT
3
SENSORS
1
3
1
3
ON
G
B
MS LINK
A
MADE IN USA
FIRE
DEPT.
STRIKE
OPEN
RADIO
RECEIVER
EXIT
LOOP
REVERSE
SENSOR
SAFETY
LOOP
CENTER
LOOP
GATE
LOCKED
RESET
MOTOR
COMMAND
PROCESSED
Green
Green Ground
Black 120Vac
Black 120Vac
White Neutral
White Neutral
Relay
Adapter
Module
(Optional)
Omni
Option Board
(Optional)
Electronic Power Strip
UL Alarm
Factory Heater
NOTE:
Wires into
main power and
draws 3 amps.
White
Wires
Black
Wires
Black
White
Reset Switch
Not Used
to
OmniControl™
Board
J7
1
2
3
4
5
6
J8
J2
J6
J5
J3
to
OmniControl™ Board
J2
J1
3
1234567
4
3
2
4
6
Chassis Ground
Input Power
120Vac, 60 Hz,
Grounded
J10
J10
Green Ground
OFF
ON
J11
J12
J13
123
Chassis Ground
Radio Harness
Strike Open
Push Button
Strike Open
Push Button
24 Volts DC
24 Volts DC
Fire Dept
Key Switch
Fire Dept
Key Switch
M/S Link
M/S Link
Class 2
Supply
Class 2
Supply
Center
Loop
Center
Loop
Safety
Loop
Safety
Loop
Radio
Receiver
Radio
Receiver
Exit
Loop
Exit
Loop
G
B
A
+
OmniControl Surge Suppressor
P/N Q410
Patent Pending
P/N Q410
Patent Pending
®
J1
J3
J2
12 3
1 2 345 6
1 2 345 67
Green
Green/
Black
White
Black
Red
1
2
3
4
Radio Receiver
315 MHz
24Vdc
OmniControl™ Board
Limit Box
Assy
Left
Right
Surge Suppressor
Master/Second Connection
Motor
3
Black
5
White
1
Green
1 HP Board
J9
64
53
Motor
1
2
Interlock
Assembly
J1
6
Green
4
2
NOTE:
See table on next page.