MSI P7N User Guide - Page 29

Fan Power Connectors: CPUFAN1, SYSFAN1~4, Chassis Intrusion Connector: JCI1

Page 29 highlights

Hardware Setup Fan Power Connectors: CPUFAN1, SYSFAN1~4 The fan power connectors support system cooling fan with +12V. W hen connecting the wire to the connectors, always note that the red wire is the positive and should be connected to the +12V; the black wire is Ground and should be connected to GND. If the mainboard has a System Hardware Monitor chipset on-board, you must use a specially designed fan with speed sensor to take advantage of the CPU fan control. Control SENSOR +12V GND CPUFAN1 NC +12V GND SYSFAN1 GND +12V NC SYSFAN2 GND +12V NC SYSFAN3 GND +12V NC SYSFAN4 Important 1. Please refer to the recommended CPU fans at processor's official website or consult the vendors for proper CPU cooling fan. 2. CPUFAN1 supports fan control. You can install Dual Core Center utility that will automatically control the these fan speed according to the actual CPU and system temperature. 3. Fan/heatsink with 3 or 4 pins are both available for CPUFAN1. Chassis Intrusion Connector: JCI1 This connector connects to the chassis intrusion switch cable. If the chassis is opened, the chassis intrusion mechanism will be activated. The system will record this status and show a warning message on the screen. To clear the warning, you must enter the BIOS utility and clear the record. 1 CINTRU 2 GND JCI1 2-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109

2-15
Hardware Setup
Important
1. Please refer to the recommended CPU fans at processor
s official website
or consult the vendors for proper CPU cooling fan.
2. CPUFAN1 supports fan control. You can install
Dual Core Center
utility
that will automatically control the these fan speed according to the actual
CPU and system temperature.
3. Fan/heatsink with 3 or 4 pins are both available for CPUFAN1.
Fan Power Connectors: CPUFAN1, SYSFAN1~4
The fan power connectors support system cooling fan with +12V. When connecting
the wire to the connectors, always note that the red wire is the positive and should
be connected to the +12V; the black wire is Ground and should be connected to GND.
If the mainboard has a System Hardware Monitor chipset on-board, you must use a
specially designed fan with speed sensor to take advantage of the CPU fan control.
Chassis Intrusion Connector: JCI1
This connector connects to the chassis intrusion switch cable. If the chassis is
opened, the chassis intrusion mechanism will be activated. The system will record
this status and show a warning message on the screen. To clear the warning, you
must enter the BIOS utility and clear the record.
JCI1
1
CINTRU
GND
2
SYSFAN4
SYSFAN3
GND
+12V
NC
SYSFAN2
SYSFAN1
CPUFAN1
Control
SENSOR
+12V
GND
NC
+12V
GND
G
N
D
+
1
2
V
N
C
GND
+12V
NC