5. Specifications SP2400 Block Diagram DIRECT L OUTPUT R L INPUT 1 R L INPUT 2 R L INPUT 3 R L INPUT 4 R +24VDC PHANTOM 2 1 PAGING MIC 3 1 3 +24VDC PHANTOM 1 MIC/LINE INPUT A 3 +24VDC PHANTOM 1 AMBIENT MIC (ZONE A) 3 GAIN +40dB GAIN +40dB GAIN +40dB GAIN +40dB GAIN GAIN INTERNAL TRIM BUS ASSIGN + TO EXPANSION I/O - + + + FROM EXPANSION - - I/O - LOCAL/REMOTE + - BUS ASSIGN + - + + FROM EXPANSION - I/O - + - TO EXPANSION I/O + - + + FROM EXPANSION - I/O - LOCAL/REMOTE LOCAL/REMOTE + - BUS ASSIGN + - + FROM + EXPANSION - I/O - + - TO EXPANSION I/O + - + + FROM EXPANSION - I/O - LOCAL/REMOTE LOCAL/REMOTE + - BUS ASSIGN + - + FROM + EXPANSION - I/O - + - TO EXPANSION I/O + - + + FROM EXPANSION - I/O - LOCAL/REMOTE LOCAL/REMOTE + + FROM + - -EXPAIN/OSION - + TO EXPANSION I/O - BUS ASSIGN TO EXPANSION I/O MIC + - LOCAL/REMOTE + LO HI - 80 12K VOX LO HI 80 12K ZONE A ZONE B ALL CALL GND PAGE MIC SWITCH CONTROL ADC TO µP +24VDC PHANTOM 1 MIC/LINE INPUT B 3 +24VDC PHANTOM AMBIENT MIC 1 (ZONE B) 3 GAIN +40dB GAIN +40dB GAIN INTERNAL TRIM LO HI 80 12K ADC TO µP TO ZONE B DIGITALLY CONTROLLED ATTENUATORS STEREO/ MONO STEREO/ MONO STEREO/ MONO STEREO/ MONO (TO µP) PAGING MIC VOX (TO µP) PAGING MIC VOX ATTENUATOR CONTROL (FROM µP) TO ZONE B TO ZONE B 3 0 3 6 WOODINVILLE REDMOND FROM µP 9 15 MACKIE INDUSTRIAL 30 55 TO ZONE B VOX ACTIVATION TO µP TO ZONE B VOX ACTIVATION TO µP TO ZONE B PROGRAM EQ LO MID FREQ HI 80 12K J6 EQ BYPASS DIGITALLY CONTROLLED ATTENUATOR J4 INSERT (INTERNAL FOR OPTIONAL DSP CARD) ADC TO µP ZONE A PRE OUT ZONE A AMP IN V+ OVERLOAD V- V+ FROM TEMP SENSOR (ON HEATSINK) PROTECTION 70V/100V 8Ω LEFT/ZONE A OUTPUT + - V- -15VDC (w/J2 INSTALLED) N/C PAGING MIC (+) INPUT 4 RIGHT (+) INPUT 4 LEFT (+) INPUT 3 RIGHT (-) INPUT 3 LEFT (-) GROUND INPUT 2 RIGHT (+) INPUT 2 LEFT (+) INPUT 1 RIGHT (-) INPUT 1 LEFT (-) EXPANSION IN 25 13 14 1 +15VDC (w/J3 INSTALLED) PAGING MIC CONTROL PAGING MIC (-) INPUT 4 RIGHT (-) INPUT 4 LEFT (-) GROUND INPUT 3 RIGHT (+) INPUT 3 LEFT (+) INPUT 2 RIGHT (-) INPUT 2 LEFT (-) GROUND INPUT 1 RIGHT (+) INPUT 1 LEFT (+) MACKIE INDUSTRIAL SP2400 BLOCK DIAGRAM (#01.02.01.DF) -15VDC (w/J2 INSTALLED) N/C PAGING MIC (+) INPUT 4 RIGHT (+) INPUT 4 LEFT (+) INPUT 3 RIGHT (-) INPUT 3 LEFT (-) GROUND INPUT 2 RIGHT (+) INPUT 2 LEFT (+) INPUT 1 RIGHT (-) INPUT 1 LEFT (-) 25 13 14 1 +15VDC (w/J3 INSTALLED) PAGING MIC CONTROL PAGING MIC (-) INPUT 4 RIGHT (-) INPUT 4 LEFT (-) GROUND INPUT 3 RIGHT (+) INPUT 3 LEFT (+) INPUT 2 RIGHT (-) INPUT 2 LEFT (-) GROUND INPUT 1 RIGHT (+) INPUT 1 LEFT (+) EXPANSION OUT SP2400 - 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

SP2400
23
3
0
3
6
9
15
30
55
DIRECT
OUTPUT
L
R
INPUT 1
DIGITALLY
CONTROLLED
ATTENUATORS
DIGITALLY
CONTROLLED
ATTENUATOR
STEREO/
MONO
L
+
R
MACKIE INDUSTRIAL
SP2400
BLOCK DIAGRAM
(#01.02.01.DF)
MACKIE
INDUSTRIAL
WOODINVILLE
REDMOND
BUS
ASSIGN
+
STEREO/
MONO
STEREO/
MONO
+24VDC
PHANTOM
PAGING MIC
GAIN
+40dB
GAIN
GAIN
+40dB
STEREO/
MONO
1
1
2
3
3
+
PAGING
MIC VOX
ATTENUATOR
CONTROL
(FROM
µ
P)
TO ZONE B
TO ZONE B
TO ZONE B
TO ZONE B
J6
EQ
BYPASS
MID FREQ
ZONE A
PRE OUT
PROGRAM EQ
ZONE A
AMP IN
V+
PROTECTION
OVERLOAD
FROM
TEMP
SENSOR
(ON HEATSINK)
V
TO
µ
P
TO ZONE B
TO ZONE B
+24VDC
PHANTOM
+24VDC
PHANTOM
TO EXPANSION I/O
MIC
+
HI
80
LO
MIC/LINE
INPUT A
GAIN
+40dB
GAIN
GAIN
+40dB
1
3
HI
80
12K
12K
LO
HI
80
12K
LO
AMBIENT MIC
(ZONE A)
AMBIENT MIC
(ZONE B)
INTERNAL
TRIM
TO
µ
P
1
3
+24VDC
PHANTOM
+24VDC
PHANTOM
MIC/LINE
INPUT B
GAIN
+40dB
GAIN
GAIN
+40dB
1
3
INTERNAL
TRIM
1
3
ADC
TO
µ
P
ADC
TO
µ
P
FROM
µ
P
ADC
V+
8
LEFT/ZONE A
OUTPUT
+
70V/100V
V
ZONE A
ZONE B
PAGE MIC
SWITCH
CONTROL
ALL CALL
GND
HI
80
LO
12K
+
BUS
ASSIGN
+
+
+
INPUT 2
L
+
R
+
+
+
+
INPUT 3
L
+
R
+
+
+
INPUT 4
L
+
R
+
TO EXPANSION I/O
BUS
ASSIGN
+
+
TO EXPANSION I/O
BUS
ASSIGN
+
+
TO EXPANSION I/O
TO EXPANSION I/O
+
FROM
EXPANSION
I/O
+
FROM
EXPANSION
I/O
+
FROM
EXPANSION
I/O
+
FROM
EXPANSION
I/O
+
FROM
EXPANSION
I/O
+
FROM
EXPANSION
I/O
+
FROM
EXPANSION
I/O
+
FROM
EXPANSION
I/O
BUS
ASSIGN
+
TO EXPANSION I/O
LOCAL/REMOTE
LOCAL/REMOTE
LOCAL/REMOTE
LOCAL/REMOTE
LOCAL/REMOTE
LOCAL/REMOTE
LOCAL/REMOTE
LOCAL/REMOTE
+
+
EXPANSION IN
EXPANSION OUT
(TO
µ
P)
PAGING
MIC VOX
(TO
µ
P)
J4
INSERT
(INTERNAL
FOR OPTIONAL
DSP CARD)
VOX
VOX
ACTIVATION
TO
µ
P
VOX
ACTIVATION
+15VDC (w/J3 INSTALLED)
15VDC (w/J2 INSTALLED)
N/C
PAGING MIC (+)
INPUT 4 RIGHT (+)
INPUT 4 LEFT (+)
INPUT 3 RIGHT (
)
INPUT 3 LEFT (
)
GROUND
INPUT 2 RIGHT (+)
INPUT 2 LEFT (+)
INPUT 1 RIGHT (
)
INPUT 1 LEFT (
)
PAGING MIC CONTROL
PAGING MIC (
)
INPUT 4 RIGHT (
)
INPUT 4 LEFT (
)
GROUND
INPUT 3 RIGHT (+)
INPUT 3 LEFT (+)
INPUT 2 RIGHT (
)
INPUT 2 LEFT (
)
GROUND
INPUT 1 RIGHT (+)
INPUT 1 LEFT (+)
1
14
25
13
+15VDC (w/J3 INSTALLED)
15VDC (w/J2 INSTALLED)
N/C
PAGING MIC (+)
INPUT 4 RIGHT (+)
INPUT 4 LEFT (+)
INPUT 3 RIGHT (
)
INPUT 3 LEFT (
)
GROUND
INPUT 2 RIGHT (+)
INPUT 2 LEFT (+)
INPUT 1 RIGHT (
)
INPUT 1 LEFT (
)
PAGING MIC CONTROL
PAGING MIC (
)
INPUT 4 RIGHT (
)
INPUT 4 LEFT (
)
GROUND
INPUT 3 RIGHT (+)
INPUT 3 LEFT (+)
INPUT 2 RIGHT (
)
INPUT 2 LEFT (
)
GROUND
INPUT 1 RIGHT (+)
INPUT 1 LEFT (+)
1
14
25
13
5.
Specifications